| поискавой системы для электроныых деталей |
|
SPSB081 датащи(PDF) 34 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
SPSB081 датащи(HTML) 34 Page - STMicroelectronics |
|
34 / 137 page ![]() • The overvoltage bit VS_OV (SR2) is set and can be cleared with a ‘read and clear’ command. The overvoltage bit is reset automatically if VS_LOCK_EN (CR3) = 0 and the overvoltage condition has recovered. VS undervoltage If the supply voltage VS drops below the under voltage threshold voltage (VSUV): • LIN remains enabled • CAN remains enabled Note: The functionality is not guaranteed in the range VPOR < VSREG < VSREGUV • OUT1, OUT2, OUT3, and OUT4 are turned off (default). The shutdown of outputs may be disabled by SPI (VS_UV_SD_EN (CR3) = 0) • Recovery of outputs after undervoltage condition is configurable by SPI: – VS_LOCK_EN (CR3) = 1: Outputs are off until read and clear VS_UV (SR2) – VS_LOCK_EN (CR3) = 0: Outputs turned on automatically after VS undervoltage condition has recovered. • The undervoltage bit (VSUV) is set and can be cleared with a ‘read and clear’ command. The undervoltage bit is removed automatically if VS_ LOCK_EN = 0 and the undervoltage condition has recovered. 3.13.2 VSREG supply failure VSREG overvoltage If the supply voltage VSREG reaches the overvoltage threshold VSREGOV: • LIN is switched to high impedance (RX is still on) • CAN remains enabled • The over voltage bit VSREG_OV (SR2) is set and can be cleared with a ‘read and clear’ command. The overvoltage bit is reset automatically if VSREG_ LOCK_EN (CR3) = 0 and the overvoltage condition has recovered. VSREG undervoltage If the supply voltage VSREG drops below the under voltage threshold voltage (VSREG_UV): • LIN is switched to high impedance (RX is still on). Note: The functionality is not guaranteed in the range VPOR < VSREG < VSREGUV • CAN remains enabled • The undervoltage bit (VSREG_UV (SR2) is set and can be cleared with a ‘read and clear’ command. The undervoltage bit is removed automatically if VSREG_LOCK_EN (CR3) = 0 and the undervoltage condition has recovered. SPSB081 Power supply fail DS14048 - Rev 3 page 34/137 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |