| поискавой системы для электроныых деталей |
|
SPSB081 датащи(PDF) 19 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
SPSB081 датащи(HTML) 19 Page - STMicroelectronics |
|
19 / 137 page ![]() In standby modes, the inputs are configurable with an internal pull-up or pull-down current source according to the setup of the external contact. Moreover, in case of cyclic sensing, an internal pull-down resistor (RWU_ACT) is periodically activated on each rising edge of the TIMER_ON. RWU_ACT is activated also for static wake-up, but in this case it occurs just after WU request (see the figure above), keeping this condition for at least the filter time tWU_STAT (or more, if the WU is valid and the device enters in active mode). In active mode, the inputs have in fact only the internal pull-down resistor and the input status can be read by SPI. Static sense should be configured before the read operation is started to reflect the actual input level. Being DIR/WU2_EN enable bit, in config register (0x3F), set to 0 by default, the DIR/WU2 pin is configured as wake-up function. If DIR/WU2_EN enable bit is set to 1 the DIR/WU2 pin is a low voltage direct driving of OUT1..4. Threshold is set in this case at 1.5 V. 3.5 Functional overview (truth table) Table 8. Functional overview Version Function Comments Operating modes Active mode V1_standby static mode (cyclic sense) VBAT_standby static mode (cyclic sense) 3.4.1 Voltage regulator V1 VOUT = 5 V/3.3 V On On(1) Off 3.4.2 Voltage regulator V2 VOUT = 5 V/3.3 V On/Off(2) On(2)/Off On(2)/Off 3.4.3 Reset generator - On On Off 3.4.4 Window watchdog V1 monitor On Off (On if IV1 > ICMP and ICMP = 0) Off 3.4.5 Wake-up - Off Active(3) Active(3) 3.4.6 HS-cyclic supply Oscillator time base On/Off On(2)/Off On(2)/Off 3.4.7 LIN LIN ISO 17987-4/2016 On(2) Off(4) Off(4) 3.4.8 CAN FD - On/Off(5) Off(4) Off(4) 3.4.9 Oscillator - On On/Off(6) On/Off(6) 3.4.10 VS monitor - On(7) On/Off(7) On/Off(7) 3.4.11 OUT1 (P-channel HS) - On/Off(2) On/Off(2) On/Off(2) 3.4.12 OUT2 (P-channel HS) - On/Off(2) On/Off(2) On/Off(2) 3.4.13 OUT3 (P-channel HS) - On/Off(2) On/ Off(2) On/Off(2) 3.4.14 OUT4 (P-channel HS) - On/Off(2) On/ Off(2) On/Off(2) 3.4.15 Thermal shutdown TSD2 - On On Off 3.4.16 Thermal shutdown TSD1x (for P-channel HS) - On On(8) On/Off(2) 1. Supply the processor in low current mode. 2. According to SPI setting. 3. Unless disabled by SPI. 4. The bus state is internally stored when going to standby mode. A change of bus state will lead to a wake-up after exceeding of internal filter time (if wake up by LIN or CAN is not disabled by SPI). 5. After power-on, the CAN FD transceiver is in ‘CAN Trx standby’ mode. It is activated by SPI command (CAN_ACT = 1). 6. ON, if is enabled at least one of the following: cyclic sense, OUT1, OUT2, OUT3, OUT4, V2. 7. ON when at least one OUTx is enabled and OFF when OUTx are disabled. 8. V1, V2, OUT1, OUT2, OUT3, and OUT4 are thermal monitored. SPSB081 Functional overview (truth table) DS14048 - Rev 3 page 19/137 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |