| поискавой системы для электроныых деталей |
|
MFS5600AMBAFES датащи(PDF) 60 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MFS5600AMBAFES датащи(HTML) 60 Page - NXP Semiconductors |
|
60 / 118 page ![]() NXP Semiconductors FS5600 Automotive buck regulator and controller with voltage monitors and watchdog timer aaa-037161 BOS and Internal Core Power Up Any state after Internal Core Power Up ABIST/LBIST Complete/Bypassed J I2 EN1 or EN2 = HIGH EN1 = EN2 = LOW I1 A G H B K F C D2 E1 D1 E2 Wait for valid VDIG, VCC BIST (optional) Any State after BIST Thermal Shutdown Deep Fail Safe (FS0B = 0) INIT_RUN (FS0B = 0) M L NORMAL STATE (FS0B = 1) On Demand ABIST (FS0B = 1 for D1-E1) (FS0B = 0 for D2-E2) Shutdown Mode Power Up ULPM Mode System ON Transition System OFF Power Down Figure 19. FS5600 state diagram 17.13.1 Shutdown mode This is the state of the FS5600 when a valid VIN is applied, but EN1 and EN2 pins are held low. From one of the operation modes, (INIT_RUN/NORMAL STATE/On Demand ABIST, deep fail-safe), when EN1 and EN2 = 0, the IC enters the shut-down mode through the 'Power Down' state. When entering the shut-down mode from INIT_RUN, NORMAL STATE or on-demand ABIST states, the FS5600 sequences the GPOs in the reverse order of the power-up at the appropriate time. See Section 17.13.8 for details. For example, if OTP_GPO1_DELAY is set to 1 ms, and OTP_GPO2_DELAY is set to 5 ms: • When EN1 = EN2 = 0, GPO2 is asserted low immediately, 4 ms after which GPO1 is asserted low, 1 ms after which SW1 and SW2 regulators are disabled. • FS0B is asserted low immediately after NORMAL STATE is exited. 17.13.2 Built-in self-test (BIST) Analog Built-in self-test (ABIST) and logical built-in self-test (LBIST) are executed in this state if enabled. This state is bypassed if both are disabled. 17.13.3 Power-up SW1, SW2, and the various GPOs in FS5600 are powered up in this state. SW1 and SW2 are enabled after exiting BIST or thermal shutdown and if their respective ENx pin is held high. The power-up state exits upon completion of the highest delay among OTP_GPO1_DELAY[2:0], OTP_GPO2_DELAY[2:0] and OTP_GPO3_DELAY[2:0]. FS5600 All information provided in this document is subject to legal disclaimers. © 2024 NXP B.V. All rights reserved. Product data sheet Rev. 4 — 29 April 2024 60 / 118 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |