| поискавой системы для электроныых деталей |
|
CS4525 датащи(PDF) 85 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS4525 датащи(HTML) 85 Page - Cirrus Logic |
|
85 / 91 page ![]() DS726A1 85 CS4525 9.20.2 ADC Overflow (ADCOvfl) Default = 0 Function: This bit is read only and will identify the presence of an overflow condition within the ADC. When set, in- dicates that an over-range condition is currently occurring in the CS4525 ADC signal path and has been clipped to positive or negative full scale. 9.20.3 Channel X Overflow (ChXOvfl) Default = 0 Function: These bits are read only and will identify the presence of an overflow condition anywhere in the associated channel’s signal path. When set, indicates that an over-range condition is currently occurring in the chan- nel’s signal path and has been clipped to positive or negative full scale. 9.20.4 Ramp-Up Cycle Complete (RampDone) Default = 0 Function: When set, indicates that all active channels have completed the configured ramp-up interval. 9.21 Amplifier Error Status (Address 62h) - Read Only All bits in this register are considered “level-trigger” events, meaning as long as a condition continues, the corre- sponding bit will remain set. These status bits are not affected by the interrupt mask bit and the condition of each bit can be polled. These bits will not be cleared following a read to this register, nor can they be written to cause an interrupt condition. 9.21.1 Over-Current Detected On Channel X (OverCurrX) Default = 0 Function: When set, indicates an over current condition is currently present on the corresponding amplifier output. ADCOvfl Setting ADC Overflow State 0 .......................................... An ADC overflow condition is not currently present. 1 .......................................... An ADC overflow condition is currently present. ChXOvfl Setting Channel X Overflow State 0 .......................................... An overflow condition is not currently present on channel X. 1 .......................................... An overflow condition is currently present on channel X. RampDone Setting Ramp Completion State 0 .......................................... Ramp-up interval not completed on all channels. 1 .......................................... Ramp-up interval completed on all channels. 7 6 5 432 10 OverCurr4 OverCurr3 OverCurr2 OverCurr1 ExtAmpErr UnderV ThermErr ThermWarn OverCurrX Setting Amplifier Over-Current Status 0 .......................................... An over current condition is not currently present on amplifier output X. 1 .......................................... An over current condition is currently present on amplifier output X. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |