| поискавой системы для электроныых деталей |
|
MEC1632 датащи(PDF) 67 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MEC1632 датащи(HTML) 67 Page - Microchip Technology |
|
67 / 636 page ![]() 2012-2018 Microchip Technology Inc. DS00001592B-page 67 MEC1632 Each BAR is 32 bits wide. The format of each BAR is summarized in Table 5-5, "Base Address Register Format". An LPC I/O request is translated by the BAR into an 8-bit read or write transaction on the AHB bus. The 16-bit LPC I/O address is translated into a 24-bit AHB address The Base Address Register Table is itself part of the AHB address space. It resides in the Configuration quadrant of Logical Device Ch, the LPC Interface. MASK These 7 bits are used to mask off address bits in the address match between an LPC I/O address and the Host Address field of the BARs, as described in Section 5.6.3, "Mapping LPC I/O Addresses". A block of up to 128 8-bit registers can be assigned to one base address. FRAME These 6 bits are used to specify a logical device frame number within a bus. This field is multiplied by 400h to provide the frame address within the peripheral bus address. In the MEC1632 Frame values for frames corresponding to logical devices that are not present on the MEC1632 are invalid. VALID If this bit is 1, the BAR is valid and will participate in LPC matches. If it is 0 this BAR is ignored HOST_ADDRESS These 16 bits are used to match LPC I/O addresses 5.6.3 MAPPING LPC I/O ADDRESSES A Base Address Register will match an LPC I/O address, and thus the MEC1632 will claim the LPC bus cycle, if the following relation holds: (LPC Address & ~BAR.MASK) == (BAR.LPC_Address & ~BAR.MASK) && (BAR.Valid == 1) If one of the BARs match, the LPC cycle will be claimed and the LPC request will be translated to an AHB address according to the following formula: AHB Address = FF_000h | (BAR.Frame<<10) | (LPC_Address & BAR.MASK) The formula is illustrated in Figure 5-1, "LPC BAR Mapping". Note: Software should that insure that no two BARs map the same LPC I/O address. If two BARs do map to the same address, the BAR_Conflict bit in the Host Bus Error Register is set when an LPC access targeting the BARConflict address. An EC interrupt can be generated. TABLE 5-5: BASE ADDRESS REGISTER FORMAT BYTE3 BIT D31 D30 D29 D28 D27 D26 D25 D24 BIT NAME LPC Host Address, most significant bits BYTE2 BIT D23 D22 D21 D20 D19 D18 D17 D16 BIT NAME LPC Host Address, least significant bits BYTE1 BIT D15 D14 D13 D12 D11 D10 D9 D8 BIT NAME Valid Reserved Frame BYTE0 BIT D7D6D5D4D3D2D1D0 BIT NAME Reserved Mask |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |