| поискавой системы для электроныых деталей |
|
MCP3461RT-E/ST датащи(PDF) 65 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP3461RT-E/ST датащи(HTML) 65 Page - Microchip Technology |
|
65 / 118 page ![]() 2020-2021 Microchip Technology Inc. DS20006404C-page 65 MCP3461/2/4R 5.16.3 REGISTER BIT MODIFICATIONS CAUSING DELAYED RESET/RESTART A third group of bits will generate a Reset and a Restart that induce a new start-up delay (TADC_SETUP), so that the internal analog operating points can be settled with the new settings before the new conversion is started. The Reset is immediate; the start-up timer is only restarted after a period of two MCLK periods (necessary to handle the Reset and to ensure that the Restart is synchronous with the master clock). Overall, the delay from the Reset to the actual Restart of the conversion with the new settings is then 2 MCLK + TADC_SETUP. This group includes: CONFIG0 and the RESERVED registers at addresses: 0xB and 0xC. The CONFIG0 bits induce a start-up timer delay only if they are changed to a new value. If they are overwritten with the same value, they will generate an immediate Reset and Restart. In Scan mode, the Reset and Restart feature will just restart the current conversion for this group of bits, the Scan cycle is not modified and not restarted. This third group of bits will induce a start-up timer delay, even when ADC_MODE[1:0] = 10 or if the ADC is in Standby mode. During the Reset and Restart sequence, the Reset is immediate and resets the internal phases to the original state, which can lead to a discontinuity in the clock out- put frequency if the AMCLK clock output is enabled. The Restart is synchronous with the AMCLK generation and is effective only after two MCLK periods. The Restart also generates a conversion start pulse (only after the two MCLK periods or the two MCLK + TADC_SETUP necessary for the Restart) if enabled, for the user to be able to align the system with the exact start of the new conversion. Depending on the phase between the AMCLK and the SPI commands, the 2-MCLK delay can turn into a 4-MCLK delay to ensure the proper synchronization of the device. If very precise synchronization is required, it is recommended to not change the register configu- rations (i.e., not during conversions) or to use the EN_STP = 1 setting so that the start of the conversions can be clearly determined. In MUX mode, the TIMER and SCAN registers do not generate a Reset and Restart when written, except if the SCAN register is modified to effectively enter into Scan mode. In this case, the MUX mode is superseded by the Scan mode immediately. In Scan mode, a write access of the SCAN register, during or between conversions within the Scan cycle, will create a Reset and Restart of the whole Scan sequence. Within the same conditions, a write access on the TIMER register will not create a Reset and Restart of the entire Scan sequence. However, during the TTIMER_SCAN delay between Scan cycles, a write on the SCAN register does not generate a Reset and a Restart of the entire sequence. Within the same condi- tions, a write on the TIMER register generates a Reset and a Restart of the entire sequence. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |