| поискавой системы для электроныых деталей |
|
FUSB308B датащи(PDF) 38 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
FUSB308B датащи(HTML) 38 Page - ON Semiconductor |
|
38 / 53 page ![]() FUSB308B www.onsemi.com 38 Table 30. FAULTSTAT (continued) Address: 1Fh Reset Value: 0x80 Type: Read/Write 1 to Clear Bit # Fault Status Interrupt Description (Note 32) Size (Bits) R/W/C Name 4 FORCE_DISCH_FAIL R/WC 1 0b: No Discharge Failure 1b: VBUS Discharge Failed Asserts when PWRCTRL.FORCE_DISCH is set and one of the following occurs: If VBUS_STOP_DISCH <= vSafe0V(max.) we fail to discharge VBUS to vSafe0V (max.) within tSafe0V from the time FORCE_DISCH is set. If VBUS_STOP_DISCH > vSafe0V(max.) we fail to discharge VBUS to VBUS_STOP_DISCH within tSrcSettle from the time FORCE_DISCH is set. 3 Reserved R 1 Reserved: 0b 2 Reserved R 1 Reserved: 0b 1 VCONN_OCP R/WC 1 0b: No VCONN Over−Current Detected 1b: Over current on VCONN Latched. See VCONN_ Registers to set VCONN OCP levels. 0 I2C_ERROR R/WC 1 0b: No Error 1b: I2C Error has occurred Asserts when: or SINK_TRANSMIT has been sent with TRANS- MIT_BUFFER empty (TXBYTECNT < 2). COMMAND.DisableVbusDetect is issued while sinking or sourcing VBUS.COMMAND.SinkVbus is issued while sourcing VBUSCOMMAND.SourceVbusDefaultVoltage is issued while sinking VBUS COMMAND.SourceVbusHighVoltage is issued when device is not already sourcing 5 V, is sinking, or is not capable of sourcing high voltage. Connect_Invalid State is reached. 31.VBUS_V_BIT[9:0] is the measured VBUS voltage divided by VBUS_SCALE factor. 32.Fault Status are latched and cleared when a 1 is written to the corresponding bit. 33.ALL_REGS_RESET do not get set on SW_RST Table 31. COMMAND Address: 23h Reset Value: 0x00 Type: Read/Write (Auto−Clear) Bit # Name R/W/C Size (Bits) Register Settings COMMAND Description 7:0 Command R/W 8 0001 0001b WakeI2C (no action is taken other than to wake the I2C interface) 0010 0010b DisableVbusDetect. Disable Vbus present detection: PWRSTAT.VBUS_VAL. The FUSB308B will ignore this command and assert the FAULTSTAT.I2C_ERR if it has sourcing or sinking power over Vbus enabled 0011 0011b EnableVbusDetect. Enable Vbus present detection 0100 0100b DisableSinkVbus. Disable sinking power over Vbus. This COMMAND does not disable PWRSTAT.VBUS_VAL detection 0101 0101b SinkVbus. Enable sinking power over Vbus and enable Vbus present detection. The FUSB308B will ignore this command and assert the FAULTSTAT.I2C_ERR if it has sourcing power over Vbus enabled |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |