| поискавой системы для электроныых деталей |
|
XRT75VL00D датащи(PDF) 89 Page - Exar Corporation |
|
|
|||||||||||||||||||||||||||||
XRT75VL00D датащи(HTML) 89 Page - Exar Corporation |
|
89 / 92 page ![]() XRT75VL00D REV. 1.0.3 E3/DS3/STS-1 LINE INTERFACE UNIT WITH SONET DESYNCHRONIZER 84 that are responsible for acquiring and maintaining DS1 or DS3 frame synchronization (with these DS1 or DS3 data-streams that have been de-mapped from SONET) must have re-acquired DS1 or DS3 frame synchronization within 50ms" after APS has been initiated." The LIU was designed such that the DS3 signals that it receives from a SONET Mapper device and processes will comply with the Category I Intrinsic Jitter requirements per Telcordia GR-253-CORE. Reference 1 documents some APS Recovery Time testing, which was performed to verify that the Jitter Attenuator blocks (within the LIU) device that permit it to comply with the Category I Intrinsic Jitter Requirements (for DS3 Applications) per Telcordia GR-253-CORE, do not cause it to fail to comply with the "APS Completion Time" requirements per Section 5.3.3.3 of Telcordia GR-253-CORE. However, Table 3 presents a summary of some APS Recovery Time requirements that were documented within this test report. Table 3, NOTE: The APS Completion (or Recovery) time requirement is 50ms. Configuring the LIU to be able to comply with the SONET APS Recovery Time Requirements of 50ms Quite simply, the user can configure a given Jitter Attenuator block (associated with a given channel) to (1) comply with the "APS Completion Time" requirements per Telcordia GR-253-CORE, and (2) also comply with the "Category I Intrinsic Jitter Requirements per Telcordia GR-253-CORE (for DS3 applications) by making sure that Bit 4 (SONET APS Recovery Time Disable Ch_n), within the Jitter Attenuator Control Register is set to "0" as depicted below. TABLE 20: MEASURED APS RECOVERY TIME AS A FUNCTION OF DS3 PPM OFFSET DS3 PPM OFFSET (PER W&G ANT-20SE) MEASURED APS RECOVERY TIME (PER LOGIC ANALYZER) -99 ppm 1.25ms -40ppm 1.54ms -30 ppm 1.34ms -20 ppm 1.49ms -10 ppm 1.30ms 0 ppm 1.89ms +10 ppm 1.21ms +20 ppm 1.64ms +30 ppm 1.32ms +40 ppm 1.25ms +99 ppm 1.35ms JITTER ATTENUATOR CONTROL REGISTER - CHANNEL 0 ADDRESS LOCATION = 0X07 CHANNEL 1 ADDRESS LOCATION = 0X0F CHANNEL 2 ADDRESS LOCATION = 0X17 BIT 7BIT 6BIT 5 BIT 4BIT 3BIT 2BIT 1BIT 0 Unused SONET APS Recovery Time Disable Ch_n JA RESET Ch_n JA1 Ch_n JA in Tx Path Ch_n JA0 Ch_n |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |