| поискавой системы для электроныых деталей |
|
TLV320AIC21 датащи(PDF) 34 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TLV320AIC21 датащи(HTML) 34 Page - Texas Instruments |
|
34 / 56 page ![]() www.ti.com 1 1 1 D11 0 1 1 1 X 1 DIN (Read) DIN (Write) Don’t care D15 D15 D13 D14 D13 D14 0 D9 D10 D11 DOUT (Read) D15 D13 D14 D12 Data to be Written Into Register D7 - D0 D7 - D0 D7 - D0 R/W Broadcast Register Address Register Address SMARTDM Device Address Register Content Master FS DIN Master Slave2 Slave1 Slave0 Master Slave2 Slave1 Slave0 Master Slave2 Slave1 Slave0 Slave0 Write Command Reg Addr (D15-D13) R/W (D12) Broadcast (D11) D10-D8 001 0 1 111 010 0 1 111 100 0 1 111 110 0 1 111 Data Frame Control Frame Time Slot AIC20 #1 AIC20 #2 AIC20 #1 AIC20 #2 Data Frame Host Port Interface TLV320AIC20, TLV320AIC21 TLV320AIC24, TLV320AIC25 TLV320AIC20K, TLV320AIC24K SLAS363D – MARCH 2002 – REVISED APRIL 2005 Figure 29. Control Frame Data Format A. NOTE: In this example, the broadcast operation (D11 = 1) is used to program the four control registers of Reg.1, Reg.2, Reg.4, and Reg.6 in all four DSP codecs of two TLV320AIC2xs in cascade (Master, Slave2, Slave1, and Slave0) during the same frame (i.e., register 1 of the four codecs contains the same data). The host port uses a 2-wire serial interface (SCL, SDA) to program channel six of each of the codec control registers, and selectable protocol between S 2C mode and I2C mode. The S2C is a write-only mode, and the I2C is a read-write mode selected by bits D1-D0 (HPC bits) of control register 2. If the host interface is not needed, the two pins of SCL and SDA can be programmed to become general-purpose I/Os. If selected to be used as I/O pins, the SDA and SCL pins become output and input pins respectively, determined by D1 and D0. Both S 2C and I2C require a SMARTDM device address to communicate with the AIC2x. One of SMARTDM's advanced features is the automatic cascade detection (ACD) that enables SMARTDM to automatically detect the total number of codecs in the serial connection and use this information to assign each codec a distinct SMARTDM device address. Table 2 lists device addresses assigned to each codec in the cascade by the SMARTDM. The master always has the highest position in the cascade. For example in Figure 20, there is a total of 4 codecs in the cascade (i.e., one master and 3 slaves), then the device addresses in row 4 are used in which the master is codec 1 with a device address of 0000. 34 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |