13 / 63 page ![]() HT9580 13 April 28, 2000 Preliminary When BZ-L and BZ-H are all 00H, the tone gen- erator is disabled and BZ is high. The value of the frequency divider, ranges from 2 (BZ-L=01H, BZ-H=00H)~65536 (BZ-L=FFH, BZ-H=FFH). Writing to BZ-L only writes the data into a low byte buffer, while writing to BZ-H will write the high byte data and the con- tents of the low byte buffer into the PFD coun- ter. When the buzzer generator is disabled by clearing the ²MGEN² bit in the configuration register (0000H), the BZ pin remains at its last state. If the BZ pin is low, the BZ transistor in the application circuits is always active. There- fore it is recommended that both BZ-L and BZ-H be cleared and that the ²MGEN² bit in the configuration register (0000H) also be cleared, when it is desired to disable or stop the buzzer. The output of the 16-bit PFD counter is divided by 2 to generate a BZ output with or without modulation. For example, if the desired output of BZ is 1.6kHz with modulation and the fre- quency source is X1-clock (76.8kHz), then the value of 16-bit PFD counter is set to BZ-L=17H, BZ-H=00H and ²MDUT² is set high. Sy s t e m C l o c k MG E N B Z _C LK = 0 X1- c l o c k B Z _C LK = 1 16- bi t P F D C ount er B Z _C LK PW M M o dul at o r BZ X1- c l o c k MD U T ¸ 2 M DUT = 0 M DUT = 1 Interrupt registers Address Register Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 State on POR 0005H INT ctrl 0 0 0 RTCEN ORMSK RTCMSK TM1IMSK TM0IMSK 0000 1111 0006H INT flag 0 RTC_FG DR_FG BF_FG WDTOVFG OR_FG TM1OVFG TM0OVFG 0000 0000 There are two interrupts for the HT9580: a Non-Mask Interrupt (NMI) and a generic inter- rupt request (IRQ). The data ready interrupt and battery fail interrupt share the NMI call lo- cation. Which interrupt occurred can be deter- mined by checking bit BF_FG and the data ready interrupt bit DR_FG or SPI complete flag SPIFG (in SPI-CONFIG register). DR_FG is the data ready interrupt indication bit. When a valid call is detected, data begins to transfer. Either one call is terminated or a message buffer is full or one batch is over but the mes- sage is not terminated, the data ready inter- rupt will occur and DR_FG is set high. The DR_FG bit should be cleared low by the mC soft- ware after a data ready condition has occurred. A battery fail condition is triggered by a high to low transition on pin BAF and will set the bat- tery fail interrupt request flag BF_FG to logic high. For details, refer to the POCSAG Decoder section. The sources for the IRQ are timer 0 overflow, timer 1 overflow, out-of-range status changes and RTC time out. The four interrupt sources all could be masked, but the four corre- sponding interrupt flags will still be set when the interrupt conditions are met. All the four flags are readable/writeable. When an inter- rupt condition is met, a flag will be set. If an in- terrupt routine is performed, the software should check which flag is set to high then de- termine what kind of interrupt source occurred. The WDTOVFG is the flag for the watchdog |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |