18 / 28 page ![]() ADF4151 Data Sheet Rev. B | Page 18 of 28 MUXOUT The on-chip multiplexer is controlled by Bits[DB28:DB26] (see Figure 21). Reference Doubler Setting DB25 to 0 feeds the REFIN signal directly to the 10-bit R counter, disabling the doubler. Setting this bit to 1 multiplies the REFIN frequency by a factor of 2 before feeding into the 10-bit R counter. When the doubler is disabled, the REFIN falling edge is the active edge at the PFD input to the fractional synthesizer. When the doubler is enabled, both the rising and falling edges of REFIN become active edges at the PFD input. When the doubler is enabled and the lowest spur mode is chosen, the in-band phase noise performance is sensitive to the REFIN duty cycle. The phase noise degradation can be as much as 5 dB for the REFIN duty cycles outside a 45% to 55% range. The phase noise is insensitive to the REFIN duty cycle in the lowest noise mode. The phase noise is insensitive to the REFIN duty cycle when the doubler is disabled. When the doubler is enabled, the maximum allowable REFIN frequency is 30 MHz. RDIV2 Setting the DB24 bit to 1 inserts a divide-by-2 toggle flip-flop between the R counter and PFD, which extends the maximum REFIN input rate. This function allows a 50% duty cycle signal to appear at the PFD input, which is necessary for cycle slip reduction. 10-Bit R Counter The 10-bit R counter allows the input reference frequency (REFIN) to be divided down to produce the reference clock to the PFD. Division ratios from 1 to 1023 are allowed. Current Setting Bits[DB12:DB9] set the charge pump current setting. This should be set to the charge pump current that the loop filter is designed with (see Figure 21). LDF Setting DB8 to 1 enables integer-N digital lock detect, when the FRAC part of the divider is zero; setting DB8 to 0 enables fractional-N digital lock detect. Lock Detect Precision (LDP) When DB7 is set to 0, the fractional-N digital lock detect is activated. In this case after setting DB7 to 0, 40 consecutive PFD cycles of 10 ns must occur before digital lock detect is set. When DB7 is programmed to 1, 40 consecutive reference cycles of 6 ns must occur before digital lock detect goes high. Setting DB8 (LDF) to 1 causes the activation of the integer-N digital lock detect. In this case, after setting DB7 (LDP) to 0, five consecutive cycles of 10 ns must occur before digital lock detect is set. When DB7 is set to 1, five consecutive cycles of 6 ns must occur. Recommended settings of both the LDP and LDF bits are shown in Table 6. Table 6. Recommended LDF/LDP Bit Settings Mode DB8 (LDF) DB7 (LDP) Integer-N 1 1 Fractional-N Low Noise Mode 0 1 Fractional-N Low Spur Mode 0 0 Phase Detector Polarity DB6 sets the phase detector polarity. When a passive loop filter or noninverting active loop filter is used, set this bit to 1. If an active filter with an inverting characteristic is used, this bit should be set to 0. Power-Down (PD) DB5 provides the programmable power-down mode. Setting this bit to 1 performs a power-down. Setting this bit to 0 returns the synthesizer to normal operation. When in software power-down mode, the part retains all information in its registers. Only if the supply voltages are removed are the register contents lost. When a power-down is activated, the following events occur: • The synthesizer counters are forced to their load state conditions. • The charge pump is forced into three-state mode. • The digital lock detect circuitry is reset. • The RFOUT buffers are disabled. • The input register remains active and capable of loading and latching data. Charge Pump (CP) Three-State DB4 puts the charge pump into three-state mode when programmed to 1. It should be set to 0 for normal operation. Counter Reset DB3 is the R counter and N counter reset bit for the ADF4151. When this bit is 1, the RF synthesizer N counter and R counter are held in reset. For normal operation, this bit should be set to 0. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |