| поискавой системы для электроныых деталей |
|
PD69104B1/F датащи(PDF) 12 Page - Microsemi Corporation |
|
|
|||||||||||||||||||||||||||||
PD69104B1/F датащи(HTML) 12 Page - Microsemi Corporation |
|
12 / 36 page ![]() 4-Port PoE Manager Microsemi Proprietary and Confidential. PD69104B1/F Datasheet Revision 2.0 9 3.14.6 I²C Timing Constraints The following table lists the characteristics of the SDA and SCL bus lines for F/A-mode I2C-bus. Table 3 • Characteristics of the SDA and SCL Bus Lines for F/A-Mode I2C-Bus Parameter Symbol Standard Mode Fast Mode Unit Min Max Min Max SCL clock frequency fSCL 0 100 0 400 kHz Hold time (repeated) START condition. After this period, the first clock pulse is generated tHD;STA 4.0 0.6 µs LOW period of the SCL clock tLOW 4.7 1.3 µs HIGH period of the SCL clock tHIGH 4.0 0.6 µs Set-up time for a repeated START condition tSU;STA 4.7 0.6 µs Data hold time: for CBUS compatible masters for I²C-bus devices tHD;DAT 5.0 01 3.452 01 0.92 µs Data set-up time tSU;STA 250 1003 ns Rise time of both SDA and SCL signals tr 1000 20 + 0.1Cb4 300 ns Fall time of both SDA and SCL signals tf 300 20 + 0.1Cb4 300 ns Set-up time for STOP condition tSU;STO 4.0 0.6 µs Bus free time between a STOP and START condition tBUF 4.7 1.3 µs Capacitive load for each bus line Cb 400 400 pF Noise margin at the LOW level for each connected device (including hysteresis) VnL 0.1 VDD 0.1 VDD V Noise margin at the HIGH level for each connected device (including hysteresis) VnH 0.2 VDD 0.2 VDD V 1. A device must internally provide a hold time of at least 300 ns for the SDA signal (refers to the VIHmin of the SCL signal) to bridge the undefined region of the falling edge of the SCL. 2. The maximum tHD;DAT has to be met only if the device does not stretch the LOW period (tLOW) of the SCL signal. 3. A fast mode I2C bus device can be used in a standard mode I2C bus system, but the requirement tSU;DAT ³ 250 ns must then be met. This is in case the device does not stretch the LOW period of the SCL signal. 4. If the device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line tr max + tSU;DAT = 1000 ns + 250 ns = 1250 ns (according to the Standard-mode I2C-bus specification) before the SCL line can be released. Note: All values refer to V and V levels (see ). IHmin ILmax Electrical Characteristics (see page 13) The following illustration shows the definition of timing for F/S-mode devices on the I2C-bus. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |