| поискавой системы для электроныых деталей |
|
CS4525 датащи(PDF) 35 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS4525 датащи(HTML) 35 Page - Cirrus Logic |
|
35 / 98 page ![]() DS726PP1 35 CS4525 6.1.4.8 Bass Management The CS4525 implements a dedicated stereo 24 dB/octave Linkwitz-Riley crossover with adjustable cross- over frequency to achieve bass management for 2.1 configurations. The filter’s stereo high-pass outputs are used to drive the full-range speakers, and its stereo low-pass outputs are each attenuated by 6 dB and summed to drive the sub channel. The bass management crossover is implemented with one of two preset internal filter sets. One set is op- timized for a 32 kHz sample rate, and the other is optimized for 44.1 kHz, 48 kHz, and 96 kHz sample rates. The CS4525 automatically detects the input sample rate and chooses the appropriate filter set to apply. The available bass management cross-over frequencies are shown in Table 4 below and are con- figured with the BassMgr[2:0] bits in the EQ Config register. Note that the corner frequency of each filter set scales linearly with the input sample rate. When the internal ADC is used as the serial audio data source, the input sample rate is nominally 48 kHz and the corresponding shelving frequency corners are available. The BassMgr[2:0] bits also allow the bass manager to be disabled. When disabled, the bass management crossover is bypassed and no signal is presented on the sub channel. To allow full-range headphone operation, when the HP_DETECT/MUTE pin is configured for headphone detection (the HP/Mute bit is set), the operation of the bass manager is affected by the active state of the headphone detection input signal. In this configuration, when the bass manager is enabled, (BassMgr[2:0] bits not equal to ‘000’) and the headphone detection input signal becomes active, the bass manager will be automatically disabled. When the headphone detection input signal becomes inactive, the bass man- ager will be automatically reconfigured to operate as dictated by the BassMgr[2:0] bits. Input Sample Rate 32 kHz 44.1 kHz 48 kHz, 96 kHz Bass Manager Freq 1 80 Hz 77 Hz 83 Hz Bass Manager Freq 2 120 Hz 115 Hz 125 Hz Bass Manager Freq 3 160 Hz 153 Hz 167 Hz Bass Manager Freq 4 200 Hz 192 Hz 209 Hz Bass Manager Freq 5 240 Hz 230 Hz 250 Hz Bass Manager Freq 6 280 Hz 268 Hz 292 Hz Bass Manager Freq 7 320 Hz 307 Hz 334 Hz Table 4. Bass Management Cross-Over Frequencies Referenced Control Register Location BassMgr[2:0] ....................... “Bass Cross-Over Frequency (BassMgr[2:0])” on page 79 HP/Mute .............................. “HP_Detect/Mute Pin Mode (HP/Mute)” on page 70 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |