| поискавой системы для электроныых деталей |
|
CS4525 датащи(PDF) 63 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS4525 датащи(HTML) 63 Page - Cirrus Logic |
|
63 / 98 page ![]() DS726PP1 63 CS4525 6.6.3 Right-Justified Data Format In Right-Justified format, data is received most significant bit first and with the least significant bit present- ed on the last SCLK before the LRCK transition and is valid on the rising edge of SCLK. For the Right- Justified format, the left channel data is presented when LRCK is high and the right channel data is pre- sented when LRCK is low. 16, 18, 20, and 24 bits per sample are supported. 6.7 Integrated VD Regulator The CS4525 includes two internal linear regulators, one from the VD supply voltage to provide a fixed 2.5 V supply to its internal digital blocks, and another from the VD supply voltage to provide a fixed 2.5 V supply to its internal analog blocks. The LVD pin must be set to indicate the voltage present on the VD pin as shown in Table 21 below. The output of the digital regulator is presented on the VD_REG pin and may be used to provide an external device with up to 3mA of current at its nominal output voltage of 2.5 V. The output of the analog regulator is presented on the VA_REG pin and must only be connected to the bypass capacitors as shown in the typ- ical connection diagrams. If a nominal supply voltage of 2.5 V is used as the VD supply (see the Recommended Operating Conditions table on page 18), the VD, VD_REG, and VA_REG pins must all be connected to the VD supply source. In this configuration, the internal regulators are bypassed and the external supply source is used to directly drive the internal digital and analog sections. VD Connection VD_REG Connection VA_REG Connection LVD Connection SelectVD Bit Setting Software Mode Only 5 V Supply Bypass Capacitors Only Bypass Capacitors Only VD ‘1’ - Default 3.3 V Supply Bypass Capacitors Only Bypass Capacitors Only DGND ‘1’ - Default 2.5 V Supply VD and Bypass Capacitors VD and Bypass Capacitors DGND ‘0’ Table 21. Power Supply Configuration and Settings Referenced Control Register Location SelectVD ............................. “Select VD Level (SelectVD)” on page 88 Left Channel Right Channel 65432 10 98 7 15 14 13 12 11 10 6 5 43 210 98 7 15 14 13 12 11 10 SDIN LRCK SCLK Figure 32. Right-Justified Serial Audio Formats |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |