93 / 98 page ![]() DS726PP1 93 CS4525 9.21.5 Ramp-Up Cycle Complete (RampDone) Function: When set, indicates that all active channels have completed the configured ramp-up interval. 9.22 Amplifier Error Status (Address 62h) - Read Only All bits in this register are considered “level-triggered” events, meaning as long as a condition continues, the corre- sponding bit will remain set. These status bits are not affected by the interrupt mask bit and the condition of each bit can be polled. These bits will not be cleared following a read to this register, nor can they be written to cause an interrupt condition. 9.22.1 Over-Current Detected On Channel X (OverCurrX) Function: When set, indicates an over current condition is currently present on the corresponding amplifier output. 9.22.2 External Amplifier State (ExtAmpSt) Function: When set, indicates a thermal warning condition is currently being reported by an external amplifier. For proper operation, the delay serial port must be configured to support an external thermal warning input signal. This status bit reflects the active state of the external thermal warning input signal. 9.22.3 Under Voltage / Thermal Error State (UVTE[1:0]) Function: Indicates the operational status of the amplifier. These bits can identify a Thermal Warning condition, a Thermal Error condition, or an Under Voltage condition. The thresholds for each of these conditions is listed in the PWM Power Output Characteristics table on page 20. RampDone Setting Ramp Completion State 0 ..........................................Ramp-up interval not completed on all channels. 1 ..........................................Ramp-up interval completed on all channels. 7 6 5 432 10 OverCurr4 OverCurr3 OverCurr2 OverCurr1 ExtAmpErr Reserved UVTE1 UVTE0 OverCurrX Setting Amplifier Over-Current Status 0 ..........................................An over current condition is not currently present on amplifier output X. 1 ..........................................An over current condition is currently present on amplifier output X. ExtAmpSt Setting External Amplifier Status 0 ..........................................A thermal warning condition is not currently being reported by an external amplifier. 1 ..........................................A thermal warning condition is currently being reported by an external amplifier. UVTE[1:0] Setting Under Voltage & Thermal Error Status 00 ........................................The device is operating normally. 01 ........................................The device is operating normally; however a Thermal Warning condition is being reported. 10 ........................................An Under Voltage condition is currently present. 11.........................................A Thermal Error condition is currently present. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |