| поискавой системы для электроныых деталей |
|
AT83SND2CMP3 датащи(PDF) 71 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
AT83SND2CMP3 датащи(HTML) 71 Page - ATMEL Corporation |
|
71 / 97 page ![]() 71 AT83SND2CMP3 7524B–MP3–05/06 Framing Error Detection (Modes 1, 2 and 3) Framing error detection is provided for the three asynchronous modes. To enable the framing bit error detection feature, set SMOD0 bit in PCON register as shown in Figure 67. When this feature is enabled, the receiver checks each incoming data frame for a valid stop bit. An invalid stop bit may result from noise on the serial lines or from simultaneous transmission by 2 devices. If a valid stop bit is not found, the software sets FE bit in SCON register. Software may examine FE bit after each reception to check for data errors. Once set, only software or a chip reset clear FE bit. Subsequently received frames with valid stop bits cannot clear FE bit. When the framing error detection feature is enabled, RI rises on stop bit instead of the last data bit as detailed in Figure 73. Figure 67. Framing Error Block Diagram Baud Rate Selection (Modes 1 and 3) In modes 1 and 3, the Baud Rate is derived either from the Timer 1 or the Internal Baud Rate Generator and allows different baud rate in reception and transmission. As shown in Figure 68 the selection is done using RBCK and TBCK bits in BDRCON register. Figure 69 gives the baud rate calculation formulas for each baud rate source while Table 56 details Internal Baud Rate Generator configuration for different peripheral clock frequencies and giving baud rates closer to the standard baud rates. Figure 68. Baud Rate Source Selection (Modes 1 and 3) Figure 69. Baud Rate Formulas (Modes 1 and 3) SM0 1 0 SMOD0 PCON.6 SM0/FE SCON.7 Framing Error Controller FE 0 1 RBCK BDRCON.2 T1 CLOCK To Serial IBRG CLOCK Rx Port 0 1 TBCK BDRCON.3 T1 CLOCK To Serial IBRG CLOCK Tx Port ÷ 16 ÷ 16 Baud_Rate= 6(1-SPD) ⋅ 32 ⋅ (256 -BRL) 2SMOD1 ⋅ F PER BRL= 256 - 6(1-SPD) ⋅ 32 ⋅ Baud_Rate 2 SMOD1 ⋅ F PER Baud_Rate= 6 ⋅ 32 ⋅ (256 -TH1) 2SMOD1 ⋅ F PER TH1= 256 - 192 ⋅ Baud_Rate 2 SMOD1 ⋅ F PER a. IBRG Formula b. T1 Formula |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |