| поискавой системы для электроныых деталей |
|
AD4697BCPZ датащи(PDF) 97 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD4697BCPZ датащи(HTML) 97 Page - Analog Devices |
|
97 / 107 page ![]() Data Sheet AD4697/AD4698 REGISTER INFORMATION analog.com Rev. 0 | 97 of 107 Table 43. Bit Descriptions for ALERT_STATUS2 Bits Bit Name Description Reset Access automatically clears if a subsequent IN4 conversion is within the range set by the HYSTERESIS field in the HYST_IN4 register (see the Alert Indicator Registers section). 0 HI_IN4 IN4 Upper Alert Indicator. This bit is set to 1 when a conversion result for IN4 is greater than or equal to the IN4 upper threshold value. This indicator is only active if the threshold detection is enabled on IN4 (see the Threshold Detection and Alert Indicators section). This bit is read to clear. When the ALERT_MODE bit in the setup register is set to 1, this bit also automatically clears if a subsequent IN4 conversion is within the range set by the HYSTERESIS field in the HYST_IN4 register (see the Alert Indicator Registers section). 0x0 R Clamp Status Register Address: 0x001A, Reset: 0x00, Name: CLAMP_STATUS Table 44. Bit Descriptions for CLAMP_STATUS Bits Bit Name Description Reset Access [7:0] INX_CLAMP_FLAG[7:0] INx Overvoltage Clamp Flags. This field indicates if the INx overvoltage protection clamps are active because of an overvoltage event. Each bit corresponds to one of the analog inputs (IN0 to IN7), where INX_CLAMP_FLAG, Bit x corresponds to the INx overvoltage protection clamp status. INX_CLAMP_FLAG, Bit x is set to 1 when the INx overvoltage protection clamp is active. These bits are not sticky and are automatically cleared when the corresponding overvoltage protection clamp deactivates. 0x0 R Device Setup Register Address: 0x0020, Reset: 0x10, Name: Setup Table 45. Bit Descriptions for Setup Bits Bit Name Description Reset Access 7 ALERT_MODE Alert Mode Select Bit. This bit determines how the upper and lower alert indicators (HI_INn and LO_INn) are cleared (see the Alert Indicator Registers section). 0x0 R/W 0: hysteresis enabled. 1: hysteresis disabled. 6 SDO_STATE SDO State Select Bit. This bit determines the behavior of serial data output(s) at the beginning and end of conversion mode SPI frames (see the Conversion Mode Timing Diagrams section). 0x0 R/W 0: serial data output(s) hold the final value until the MSB of the next conversion data is clocked out. 1: busy indicator is enabled on the serial data output(s). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |