| поискавой системы для электроныых деталей |
|
IC-GD датащи(PDF) 20 Page - IC-Haus GmbH |
|
|
|||||||||||||||||||||||||||||
IC-GD датащи(HTML) 20 Page - IC-Haus GmbH |
|
20 / 55 page ![]() prel imin ary prel imin ary iC-GD UNIVERSAL I/O INTERFACE Rev A1, Page 20/55 Measuring ranges Range Maximum ratings Digital values Valid Range ±10 V -10.5000 V 0x8000 0x8619 . . . 0x79E7 10.4997 V 0x7FFF ±1 V -1.05000 V 0x8000 0x8619 . . . 0x79E7 1.04997 V 0x7FFF ±100 mV -105.000 mV 0x8000 0x8619 . . . 0x79E7 104.997 mV 0x7FFF ±10 mV -10.5000 mV 0x8000 0x8619 . . . 0x79E7 10.4997 mV 0x7FFF -17.5 mV. . . 87.5 mV -17.5 mV 0x8000 0x8000 . . . 0x7FFF (*) (thermo couples JKTNE) 87.498 mV 0x7FFF -4.375 mV. . . 21.875 mV -4.375 mV 0x8000 0x8000 . . . 0x7FFF (*) (thermo couples RSB) 21.8747 mV 0x7FFF ±20 mA -21 mA 0x8000 0x8619 . . . 0x79E7 20.999 mA 0x7FFF 4. . . 20 mA -13 mA 0x8000 0x0000 . . . 0x7878 4 mA 0x0000 20.999 mA 0x7FFF Table 5: Measurement ranges of the analog inputs Accuracy of measuring ranges Tj 25 °C -40...100 °C -40...120 °C ±10 V 5.25 mV 21 mV 42 mV ±1 V 0.525 mV 2.1 mV 4.2 mV ±100 mV 52.5 µV 210 µV 420 µV ±10 mV 5.25 µV 21 µV 42 µV -17.5 mV. . . 87.5 mV 26.25 µV 105 µV 210 µV -4.375 mV. . . 21.875 mV 6.56 µV 26.25 µV 52.5 µV Table 6: Accuracy of the measurement ranges depending on chip temperature Analog outputs (UPx, UNx, IAx) The positive voltage outputs UPx are current-limited and switch off, when overtemperature limit T2 is ex- ceeded. If the temperature exceeds overtemperature limit T1, the output is only disconnected, if it reports an overload at the same time. An extended current mode provides increased current capability of up to +20 mA. All negative voltage outputs UNx contain a 25 mA cur- rent source that only switches off in case of overload and when exceeding the upper overtemperature limit T2. When the short-circuit output current is reached, a seperate error bit is set for each of the states low and high. An overload is reported when the output voltage deviates from the set point by more than 1 V, since a short circuit can occur anywhere in the entire output voltage range. In combination with an external resistor and the voltage measurement (Mixed Mode), the current outputs IAx can be extended for a resistance measurement. The measuring ranges and tolerances are the same as for the individual functions. The minimum supply voltage VB = 14.5 V and the saturation voltage hi at the output IAx result in a maximum load of 600 Ω for 20 mA current output. By reaching the upper dynamic range, a high- impedance load or open wire at IAx or UIx during a 3-wire measurement can be detected. This is indicated by the relevant error bits. For this functionality, at least one output current of -10 mA must be set. If an NTC or PTC resistance is used for temperature measurement, the linearization and calibration must be carried out externally. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |