| поискавой системы для электроныых деталей |
|
L9658 датащи(PDF) 23 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9658 датащи(HTML) 23 Page - STMicroelectronics |
|
23 / 64 page ![]() L9658 Functional description Doc ID 14219 Rev 3 23/64 The following power-up conditions is considered as normal operations. VRES input can be connected to either a power supply output or an ignition voltage. VDD is connected to 5 V output of power supply. When VRES is connected to the power supply, VDD voltage will reach its regulation voltage before VRES voltage is stabilized. In this condition, the device has the control o f its internal logic and that prevent an inadvertent turn-on of the drivers. When VRES is connected to the ignition, VRES voltage will be stabilized before VDD reaches its regulation voltage. In this condition, all drivers are inactive. A pull-down on the gates of high side drivers (SQH) is provided to prevent these drivers from momentarily turning-on. Any loop driver fault conditions do not turn on the SQH and SQL drivers. Only a valid deployment condition can turn on the respective SQH and SQL drivers. Refer to section for valid deployment conditions. 4.9.1 Arming interface The arming interface is used as a fail-safe to prevent inadvertent airbag deployment. Along with deployment command, these signals provide redundancy. Pulse stretch timer is provided for each channel/loop. Either ARM signal or deployment command shall start the pulse stretch timer. Arming interface has a dedicated 8-bit SPI interface. When CS_A is negated, L9658 latch ARM signal from the shift register and start the pulse stretch timer for the respective channel/s. The device can deploy a channel, ONLY when DEPEN is asserted and any of the following conditions are satisfied: – the respective deployment command is sent during a valid pulse stretch timer, which initiated by ARM signal – the respective SPI ARM command is sent during a valid pulse stretch timer, which initiate by deployment command During a deployment, the device turn on the respective high side (SQH) and low side (SQL) drivers for duration of tDEPLOY. When a deployment is initiated, it cant be terminated, except during a reset event. Figure 11. Deployment sequence When a deployment-enable command is sent through SPI, the pulse stretcher shall be initiated immediately following the falling edge of CS_D. When another deployment-enable Pulse Stretch Timer t DEPLOY Deploy Valid Deployment Window CS _D Deploy Success Flag 1: Deployment-enable Command 2: Clear Deploy Success Flag SPI CS_D Notes: 11 2 t PULSE Valid Deployment Window 11 2 Valid Deployment Window t < t PULSE Valid Deployment Window t<t PULSE 1 3 3: Deployment-disable Command 3 ARM Status Flag CS_A A B A B A B A B A B ARMEN Notes: A: Arming-enable Command B: Arming-disable Command DEPEN input is assumed to be active in this sequence. SPI Deploy Command Status Flag t PULSE t<t PULSE A t DEPLOY 1 t PULSE Deploy Status Flag Monitor Mode Command bit D8 = 0 Deploy Status Flag Monitor Mode Command bit D8 = 1 1 t<t PULSE 3 t PULSE |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |