| поискавой системы для электроныых деталей |
|
ADP1050ACPZ-R7 датащи(PDF) 54 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1050ACPZ-R7 датащи(HTML) 54 Page - Analog Devices |
|
54 / 93 page ![]() Data Sheet ADP1050 CAPABILITY This command summarizes the PMBus optional communication protocols supported by the ADP1050. The reading of this command should result in 0x20. Table 20. Register 0x19—CAPABILITY Bits Bit Name/Function R/W Description [7] Packet error R Checks the packet error capability of the device. 0 = not supported. [6:5] Maximum bus speed R Checks the PMBus speed capability of the device. 01 = maximum bus speed of 400 kHz. 4 SMBALERT R Checks support of the SMBALERT pin and the SMBus alert response protocol. 0 = not supported. [3:0] Reserved R Reserved. VOUT_MODE The VOUT_MODE command sets the data format for output voltage related data. The data byte for the VOUT_MODE command consists of a 3-bit mode and 5-bit exponent parameter. The 3-bit mode determines whether the device uses linear format or direct format for the output voltage related commands. The 5-bit parameter sets the exponent value for linear format. Table 21. Register 0x20—VOUT_MODE Bits Bit Name/Function R/W Description [7:5] Mode R Output voltage data format. The value is fixed at 000, meaning that only linear format is supported. [4:0] Exponent R The N value for the output voltage related commands in linear format: V = Y × 2N. The value is fixed at 10110 (twos complement, −10 decimal). The exponent for linear format values is −10. VOUT_COMMAND The VOUT_COMMAND command sets the output voltage. The VOUT_TRANSITION_RATE command is used if this command is modified while the output is active and in a steady state condition. The maximum programmable output voltage is 64 V. Table 22. Register 0x21—VOUT_COMMAND Bits Bit Name/Function R/W Description [15:0] Mantissa R/W Sets the output voltage reference value, in volts. 16-bit unsigned integer Y value for linear format: V = Y × 2N. N is defined in the VOUT_MODE command. VOUT_TRIM The VOUT_TRIM command applies a fixed offset voltage to the output voltage command value. It is typically set by the user to trim the output voltage at the time that the PMBus device is assembled into the system of the user. The trim range is −32 V to +32 V, and each LSB resolution is 2−10 = 0.9765625 mV. Table 23. Register 0x22—VOUT_TRIM Bits Bit Name/Function R/W Description [15:0] Mantissa R/W Sets the output voltage trim value. 16-bit twos complement Y value for linear format: V = Y × 2N. N is defined in the VOUT_MODE command. Rev. A | Page 53 of 92 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |