22 / 35 page ![]() ADF4356 Data Sheet Rev. 0 | Page 22 of 35 Reference Mode The ADF4356 permits use of either differential or single-ended reference sources. For optimum integer boundary spur performance, it is recommended to use the single-ended setting for all references up to 250 MHz (even if using a differential reference signal). Use the differential setting for reference frequencies above 250 MHz. Level Select To assist with logic compatibility, MUXOUT is programmable to two logic levels. Set the U5 bit (Bit DB8) to 0 to select 1.8 V logic, and set it to 1 to select 3.3 V logic. Phase Detector Polarity The U4 bit (Bit DB7) sets the phase detector polarity. When a passive loop filter or a noninverting active loop filter is used, set DB7 to 1 (positive). If an active filter with an inverting characteristic is used, set this bit to 0 (negative). Power-Down The U3 bit (Bit DB6) sets the programmable power-down mode. Setting DB6 to 1 performs a power-down. Setting DB6 to 0 returns the synthesizer to normal operation. In software power-down mode, the ADF4356 retains all information in its registers. The register contents are only lost if the supply voltages are removed. When power-down activates, the following events occur: • The synthesizer counters are forced to their load state conditions. • The VCO powers down. • The charge pump is forced into three-state mode. • The digital lock detect circuitry resets. • The RFOUTA+/RFOUTA− and RFOUTB+/RFOUTB− output stages are disabled. • The input registers remain active and capable of loading and latching data. Charge Pump Three-State Setting the U2 bit (Bit DB5) to 1 puts the charge pump into three-state mode. Set DB5 to 0 for normal operation. Counter Reset The U1 bit (Bit DB4) resets the R counter, N counter, and VCO band select of the ADF4356. When DB4 is set to 1, the RF synthesizer N counter, R counter, and VCO band select are reset. For normal operation, set DB4 to 0. REGISTER 5 The bits in Register 5 are reserved and must be programmed as described in Figure 33, using a hexadecimal word of 0x00800025. DB0 DB1 DB2 DB3 DB4 DB5 DB6 DB7 DB8 DB9 DB10 DB11 DB12 DB13 DB14 DB15 DB16 DB17 DB18 DB19 DB20 DB21 DB22 DB23 DB24 DB25 DB26 DB27 DB28 DB29 DB30 DB31 C1(1) C2(0) C3(1) C4(0) 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 RESERVED CONTROL BITS Figure 33. Register 5 (0x00800025) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |