| поискавой системы для электроныых деталей |
|
P89C51RC2BA/01 датащи(PDF) 36 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
P89C51RC2BA/01 датащи(HTML) 36 Page - NXP Semiconductors |
|
36 / 68 page ![]() Philips Semiconductors Preliminary data P89C51RA2/RB2/RC2/RD2xx 80C51 8-bit Flash microcontroller family 8KB/16KB/32KB/64KB ISP/IAP Flash with 512B/512B/512B/1KB RAM 2002 Jul 18 36 CMOD Address = D9H Reset Value = 00XX X000B CIDL WDTE – – – CPS1 CPS0 ECF Bit: Symbol Function CIDL Counter Idle control: CIDL = 0 programs the PCA Counter to continue functioning during idle Mode. CIDL = 1 programs it to be gated off during idle. WDTE Watchdog Timer Enable: WDTE = 0 disables Watchdog Timer function on PCA Module 4. WDTE = 1 enables it. – Not implemented, reserved for future use.* CPS1 PCA Count Pulse Select bit 1. CPS0 PCA Count Pulse Select bit 0. CPS1 CPS0 Selected PCA Input** 0 0 0 Internal clock, fOSC/6 in 6-clock mode (fOSC/12 in 12-clock mode) 0 1 1 Internal clock, fOSC/2 in 6-clock mode (fOSC/4 in 12-clock mode) 1 0 2 Timer 0 overflow 1 1 3 External clock at ECI/P1.2 pin (max. rate = fOSC/4 in 6-clock mode, fOCS/8 in 12-clock mode) ECF PCA Enable Counter Overflow interrupt: ECF = 1 enables CF bit in CCON to generate an interrupt. ECF = 0 disables that function of CF. NOTE: * User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features. In that case, the reset or inactive value of the new bit will be 0, and its active value will be 1. The value read from a reserved bit is indeterminate. ** fOSC = oscillator frequency SU01318 7 6 5 432 1 0 Figure 28. CMOD: PCA Counter Mode Register CCON Address = D8H Reset Value = 00X0 0000B CF CR – CCF4 CCF3 CCF2 CCF1 CCF0 Bit Addressable Bit: Symbol Function CF PCA Counter Overflow flag. Set by hardware when the counter rolls over. CF flags an interrupt if bit ECF in CMOD is set. CF may be set by either hardware or software but can only be cleared by software. CR PCA Counter Run control bit. Set by software to turn the PCA counter on. Must be cleared by software to turn the PCA counter off. – Not implemented, reserved for future use*. CCF4 PCA Module 4 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF3 PCA Module 3 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF2 PCA Module 2 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF1 PCA Module 1 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. CCF0 PCA Module 0 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software. NOTE: * User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features. In that case, the reset or inactive value of the new bit will be 0, and its active value will be 1. The value read from a reserved bit is indeterminate. SU01319 76 5 4 3 210 Figure 29. CCON: PCA Counter Control Register |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |