61 / 158 page ![]() www.austriamicrosystems.com Revision 1v13 60 - 157 AS3658 Data Sheet Confidential - Detail ed Descri ption-Power Management Functions transferred to the DeltaCharge register. The CalReq bit is cleared automatically after the calibration has completed successfully and FGOffCal has been written to the register. Please note that offset calibration is not possible while the charger is active. If the CalReq bit is set while the charger is active the calibration will start automatically after the charger has been disabled by clearing the ChEn bit or if the external charge adapter has been removed. If during an offset calibration procedure the charger is enabled the offset calibration mode is terminated, the CalReq bit is cleared, the current value of the elapsed time counter is transferred to the ElapsedTime register and the DeltaCharge register is loaded with (FFFF)h. Calculation of Battery Status The host system can calculate all the parameters necessary for estimating the remaining battery capacity by evaluating ElapsedTime, DeltaCharge and FGOffCal. Calculating Elapsed Time The host system can evaluate the change in time Δt by setting the UpdReq bit in the FuelGauge register and reading ElapsedTime after UpdReq has been automatically cleared. The change in time in seconds is given by: Δt = ElapsedTime x 3600 / 4096.60 [s] (EQ 1) Note that the absolute accuracy of Δt is directly related to the absolute accuracy of the internal reference oscillator. To cancel the error associated with the accuracy of the oscillator, a correction factor CV can be introduced. CV can be evaluated by comparing the change in time calculated by (1) with some reference value ΔtREF obtained from a RTC or measured during system calibration. CV is given by: CV = ΔtREF / Δt(EQ 2) By multiplying Δt and CV the correct value for the change in time can be calculated: ΔtCORR = CV x Δt [s] (EQ 3) Calculating Average Current The host system can calculate the average current during the last time period by setting the UpdReq bit in the FuelGauge register and reading DeltaCharge and ElapsedTime after UpdReq has been automatically cleared. Together with FGOffCal determined during offset calibration mode the average current is given by: IAVG = DeltaCharge / (Δt x AVFC x Rsense) – FGOffCal x 3.05µV / Rsense [A] (EQ 4) Δt is the change in time in seconds calculated by (1), AVFC is the gain of the VFC in Hz/V, Rsense is the value of the sense resistor in Ω and FGOffCal is the offset calibration value. As DeltaCharge and Δt both are proportional to the oscillator frequency, no correction factor needs to be introduced in the formula. Calculating Accumulated Current Accumulated current is used to calculate the absolute remaining capacity of the battery. It is given by: IACC = IAVG x ΔtCORR [A] (EQ 5) Calculating the Remaining Capacity Remaining capacity is the entire goal of fuel gauging. It is given by: RC = RC + IACC [As] (EQ 6) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |