| поискавой системы для электроныых деталей |
|
S29GL01GS датащи(PDF) 43 Page - SPANSION |
|
|
|||||||||||||||||||||||||||||
S29GL01GS датащи(HTML) 43 Page - SPANSION |
|
43 / 104 page ![]() March 16, 2012 S29GL_128S_01GS_00_06 GL-S MirrorBit® Family 43 Data She e t 5.5.1 Embedded Operation Error If an error occurs during an embedded operation (program, erase, blank check, or password unlock) the device (EAC) remains busy. The RY/BY# output remains Low, data polling status continues to be overlaid on all address locations, and the status register shows ready with valid status bits. The device remains busy until the error status is detected by the host system status monitoring and the error status is cleared. During embedded algorithm error status the Data Polling status will show the following: DQ7 is the inversion of the DQ7 bit in the last word loaded into the write buffer or last word of the password in the case of the password unlock command. DQ7 = 0 for an erase or blank check failure DQ6 continues to toggle DQ5 = 1; Failure of the embedded operation DQ4 is RFU and should be treated as don’t care (masked) DQ3 = 1 to indicate embedded sector erase in progress DQ2 continues to toggle, independent of the address used to read status DQ1 = 1; Write buffer abort error DQ0 is RFU and should be treated as don’t care (masked) During embedded algorithm error status the Status Register will show the following: SR[7] = 1; Valid status displayed SR[6] = X; May or may not be erase suspended during the EA error SR[5] = 1 on erase or blank check error; else = 0 SR[4] = 1 on program or password unlock error; else = 0 SR[3] = 1; Write buffer abort SR[2] = 1; Program suspended SR[1] = 1; Protected sector SR[0] = X; RFU, treat as don’t care (masked) When the embedded algorithm error status is detected, it is necessary to clear the error status in order to return to normal operation, with RY/BY# High, ready for a new read or command write. The error status can be cleared by writing: Reset command Status Register Clear command Commands that are accepted during embedded algorithm error status are: Status Register Read Reset command Status Register Clear command |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |