| поискавой системы для электроныых деталей |
|
SC667201MMG3 датащи(PDF) 62 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
SC667201MMG3 датащи(HTML) 62 Page - Freescale Semiconductor, Inc |
|
62 / 120 page ![]() MPC5642A Microcontroller Data Sheet, Rev. 3.1 62 Freescale Semiconductor Electrical characteristics 3.5 Electrostatic discharge (ESD) characteristics 3.6 Power management control (PMC) and power on reset (POR) electrical specifications Table 13. ESD ratings1,2 1 All ESD testing is in conformity with CDF-AEC-Q100 Stress Test Qualification for Automotive Grade Integrated Circuits. 2 Device failure is defined as: “If after exposure to ESD pulses, the device does not meet the device specification requirements, which includes the complete DC parametric and functional testing at room temperature and hot temperature.” Symbol Parameter Conditions Value Unit — SR ESD for Human Body Model (HBM) — 2000 V R1 SR HBM circuit description — 1500 CSR — 100 pF — SR ESD for Field Induced Charge Model (FDCM) All pins 500 V Corner pins 750 — SR Number of pulses per pin Positive pulses (HBM) 1 — Negative pulses (HBM) 1 — — SR Number of pulses — 1 — Table 14. PMC operating conditions and external regulators supply voltage ID Name C Parameter Value Unit Min Typ Max 1TJ SR — Junction temperature –40 27 150 °C 2VDDREG SR — PMC 5 V supply voltage VDDREG 4.75 5 5.25 V 3VDD CC C Core supply voltage 1.2 V VDD when external regulator is used without disabling the internal regulator (PMC unit turned on, LVI monitor active)1 1 An internal regulator controller can be used to regulate the core supply. 1.262 2 The minimum supply required for the part to exit reset and enter in normal run mode is 1.28 V. 1.3 1.32 V 3a — CC C Core supply voltage 1.2 V VDD when external regulator is used with a disabled internal regulator (PMC unit turned-off, LVI monitor disabled) 1.14 1.2 1.32 V 4IVDD CC C Voltage regulator core supply maximum required DC output current 400 — — mA 5VDD33 CC C Regulated 3.3 V supply voltage when external regulator is used without disabling the internal regulator (PMC unit turned-on, internal 3.3V regulator enabled, LVI monitor active)3 3 An internal regulator can be used to regulate the 3.3 V supply. 3.3 3.45 3.6 V 5a — CC C Regulated 3.3 V supply voltage when external regulator is used with a disabled internal regulator (PMC unit turned-off, LVI monitor disabled) 33.3 3.6 V 6 — CC C Voltage regulator 3.3 V supply maximum required DC output current 80 — — mA |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |