| поискавой системы для электроныых деталей |
|
PCF2123TS датащи(PDF) 16 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCF2123TS датащи(HTML) 16 Page - NXP Semiconductors |
|
16 / 55 page ![]() PCF2123_2 © NXP B.V. 2009. All rights reserved. Product data sheet Rev. 02 — 4 December 2009 16 of 55 NXP Semiconductors PCF2123 SPI Real time clock/calendar During read/write operations, the time counting circuits (memory locations 02h through 08h) are blocked. This prevents • Faulty reading of the clock and calendar during a carry condition • Incrementing the time registers during the read cycle After this read/write access is completed, the time circuit is released again and any pending request to increment the time counters that occurred during the read/write access is serviced. A maximum of 1 request can be stored; therefore, all accesses must be completed within 1 second (see Figure 12). As a consequence of this method, it is very important to make a read or write access in one go, that is, setting or reading seconds through to years should be made in one single access. Failing to comply with this method could result in the time becoming corrupted. As an example, if the time (seconds through to hours) is set in one access and then in a second access the date is set, it is possible that the time may increment between the two accesses. A similar problem exists when reading. A roll over may occur between reads thus giving the minutes from one moment and the hours from the next. Therefore it is advised to read all time and date registers in one access. 9.7 Alarm function When one or more of these registers are loaded with a valid minute, hour, day, or weekday and its corresponding alarm enable bit (AE_x) is logic 0, then that information will be compared with the current minute, hour, day, and weekday. 9.7.1 Register Minute_alarm [1] Default value. Fig 12. Access time for read/write operations t < 1 s 013aaa222 COMMAND data bus chip enable DATA DATA DATA Table 18. Minute_alarm - minute alarm register (address 09h) bit description Bit Symbol Value Place value Description 7 AE_M 0 - minute alarm is enabled 1[1] - minute alarm is disabled 6 to 4 MINUTE_ALARM 0 to 5 ten’s place minute alarm information coded in BCD format 3 to 0 0 to 9 unit place |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |