номер детали TPS2480PW
подробное описание детали  Positive Voltage Intelligent Protection Device Hotswap Controller and I2C Current Monitor
PDF  60 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  TI2 [Texas Instruments]
домашняя страница  https://www.ti.com
Logo TI2 - Texas Instruments

TPS2480PW датащи(HTML) 34 Page - Texas Instruments

Back Button TPS2480PW Datasheet HTML 30Page - Texas Instruments TPS2480PW Datasheet HTML 31Page - Texas Instruments TPS2480PW Datasheet HTML 32Page - Texas Instruments TPS2480PW Datasheet HTML 33Page - Texas Instruments TPS2480PW Datasheet HTML 34Page - Texas Instruments TPS2480PW Datasheet HTML 35Page - Texas Instruments TPS2480PW Datasheet HTML 36Page - Texas Instruments TPS2480PW Datasheet HTML 37Page - Texas Instruments TPS2480PW Datasheet HTML 38Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 34 / 60 page
background image
V
=V
GND
-
BUS
IN-
Rangeof0Vto26V
TypicalApplication12V
Data(SDA)
3.3VSupply
Clock(SCL)
´
PowerRegister
CurrentRegister
I C
Interface
2
VoltageRegister
V
IN+
V
IN-
ADC
PGA
GND
A0
A1
Current
Shunt
V
=V
V
-
SHUNT
IN+
IN-
Typically<50mV
Supply
Load
-
+
3Vto5.5V
V
S
TPS2480
TPS2481
SLUS939B – APRIL 2010 – REVISED DECEMBER 2010
www.ti.com
ADC Operation
The two analog inputs to the TPS2480/81, VINP and VINM, connect to a shunt resistor in the bus of interest. The
TPS2480/81 is typically powered by a separate supply from 3 V to 5 .5V. The bus being sensed can vary from 0
V to 26 V. There are no special considerations for power-supply sequencing (for example, a bus voltage can be
present with the supply voltage off, and vice-versa). The TPS2480/81 senses the small drop across the shunt for
shunt voltage, and senses the voltage with respect to ground from VIN– for the bus voltage. Figure 25 illustrates
this operation.
Figure 25. TPS2480/81 Configured For Current and Voltage Measurement
When the TPS2480/81 is in the normal operating mode (that is, MODE bits of the Configuration Register are set
to '111'), it continuously converts the shunt voltage up to the number set in the shunt voltage averaging function
(Configuration Register, SADC bits). The device then converts the bus voltage up to the number set in the bus
voltage averaging (Configuration Register, BADC bits). The Mode control in the Configuration Register also
permits selecting modes to convert only voltage or current, either continuously or in response to an event
(triggered).
34
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): TPS2480 TPS2481



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com