Back Button INA745AIRELR Datasheet HTML 15Page - Texas Instruments INA745AIRELR Datasheet HTML 16Page - Texas Instruments INA745AIRELR Datasheet HTML 17Page - Texas Instruments INA745AIRELR Datasheet HTML 18Page - Texas Instruments INA745AIRELR Datasheet HTML 19Page - Texas Instruments INA745AIRELR Datasheet HTML 20Page - Texas Instruments INA745AIRELR Datasheet HTML 21Page - Texas Instruments INA745AIRELR Datasheet HTML 22Page - Texas Instruments INA745AIRELR Datasheet HTML 23Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 19 / 50 page
background image
6.3.7 Multi-Alert Monitoring and Fault Detection
The INA745x includes a multipurpose, open-drain ALERT output pin that can be used to report multiple
diagnostics, or to indicate that the ADC conversion is complete. The diagnostics listed in Table 6-1 are constantly
monitored and can be reported through the ALERT pin whenever the monitored output value crosses the
associated out-of-range threshold.
Table 6-1. ALERT Diagnostics Description
INA745x DIAGNOSTIC
STATUS BIT IN DIAG_ALRT REGISTER
(RO)
OUT-OF-RANGE
THRESHOLD
REGISTER (R/W)
REGISTER DEFAULT
VALUE
Current Under-Limit
CURRENTUL
CUL
0x8000 h
(2's complement)
Current Over-Limit
CURRENTOL
COL
0x7FFF h
(2's complement)
Bus Voltage Over-Limit
BUSOL
BOVL
0x7FFF h
(2's complement, positive
values only)
Bus Voltage Under-Limit
BUSUL
BUVL
0x0000 h
(2's complement, positive
values only)
Temperature Over-Limit
TMPOL
TEMP_LIMIT
0xFFFF h
(2's complement, positive
values only)
Power Over-Limit
POL
PWR_LIMIT
0x7FFF h
(2's complement)
A read of the DIAG_ALRT register is used to determine which diagnostic has triggered the ALERT pin. This
register, shown in Table 7-11, is also used to monitor other associated diagnostics as well as configure some
ALERT pin functions.
• Alert latch enable — In case the ALERT pin is triggered, this function holds the value of the pin even after
all diagnostic conditions have cleared. A read of the DIAG_ALRT register resets the status of the ALERT pin.
This function is enabled by setting the ALATCH bit.
• Conversion ready enable — Enables the ALERT pin to assert when an ADC conversion has completed and
output values are ready to be read through the digital interface. This function is enabled by setting the CNVR
bit. The conversion completed events can also be read through the CNVRF bit regardless of the CNVR bit
setting.
• Alert comparison on averaged output — Allows the out-of-range threshold value to be compared to the
averaged data values produced by the ADC. This function helps to additionally remove noise from the output
data when compared to the out-of-range threshold to avoid false alerts due to noise. However, the diagnostic
is delayed due to the time needed for averaging. This function is enabled by setting the SLOWALERT bit.
• Alert polarity — Allows the device to invert the active state of the ALERT pin. Note that the ALERT pin is an
open-drain output that must be pulled up by a resistor. The ALERT pin is active-low by default and can be
configured for active high function using the APOL control bit.
Other diagnostic functions that are not reported by the ALERT pin but are available by reading the DIAG_ALRT
register:
• Math overflow — Indicated by the MATHOF bit, reports when an arithmetic operation has caused an internal
register overflow.
• Memory status — Indicated by the MEMSTAT bit, monitors the health of the device non-volatile trim memory.
This bit always reads '1' when the device is operating properly.
• Energy overflow — Indicated by the ENERGYOF bit, reports when the ENERGY register has reached an
overflow state due to data accumulation.
• Charge overflow — Indicated by the CHARGEOF bit, reports when the CHARGE register has reached an
overflow state due to data accumulation.
www.ti.com
INA745A, INA745B
SBOSAC3B – JULY 2023 – REVISED AUGUST 2025
Copyright © 2025 Texas Instruments Incorporated
Submit Document Feedback
19
Product Folder Links: INA745A INA745B



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com