| поискавой системы для электроныых деталей |
|
L9969X датащи(PDF) 31 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9969X датащи(HTML) 31 Page - STMicroelectronics |
|
31 / 70 page ![]() Symbol Parameter Condition Min Typ Max Unit CF CF maximum output voltage - -100 mV - VDD + 200 mV V This current feedback signal could be used for certain applications. To get the direction of the current, the signal DIR (HBR control by parallel inputs) or alternatively the information from CONFIG_REG.DIR is used (HBR control by SPI). Only positive current (from Outx to GND) at the low side power stage is indicated at the CF output. Negative current and current over the bulk diode are not visible. 3.2.6.2 Current limitation The output stage current limitation levels are adjustable in 3 different ranges, as described in Table 18. The limits are guaranteed over the complete temperature range. Figure 18. Parameters during current limitation IOUT Current Limit Hysteresis IHYS t ICL Blanking Time tb Time between two transients (load dependent ) Table 18. Current limitation ranges Symbol Parameter Condition Min Typ Max Unit ICL2 Current limit, selection 2 - 4.25 5.0 5.75 A ICL3 Current limit, selection 3 (default) - 5.6 6.5 7.6 A ICL4 Current limit, selection 4 - 7.3 8.5 9.9 A ICL_HYST Current limit, hysteresis - -10 - -5 % tb Current limit, blanking time - 8 11 15 µs Note: in case of load dump with current limitations, SR=00 setting should be avoided, especially in conjunction with CL3/CL4 settings. Because the current levels are programmed by SPI, the default value is always ‘switch off current level’ = 3. A change in one or both input pins terminates the current limitation and the outputs follow the inputs respectively. If the current limitation is running and a load with a high inductive component is connected, the free wheeling may take much time. If the signal on the inputs stays unchanged, the free wheeling will last as long as the lower limit (IL - Ihys) is reached. After that, the path gets active again, the current rises until IL is reached, then an additional increase follows for tb and then free wheeling is restarted again, in case PWM is still active. The time between two transients is mainly related to the time constant of the load, and hence not specified. This time however, cannot drop below the limit ttrans_lim defined in Table 19. The information that the function “Current limitation” is active is stored in the DIA_REG2. L9969x Functional description DS14029 - Rev 6 page 31/70 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |