| поискавой системы для электроныых деталей |
|
L9969X датащи(PDF) 50 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9969X датащи(HTML) 50 Page - STMicroelectronics |
|
50 / 70 page ![]() Bit 7 6 5 4 3 2 1 0 ENDISR x x x 1 1 x x x DISR x x x x x x x x RDR x x x 1 1 x x x Controller access: read/write (write-access: WR_STATCON) (read-access: RD_STATCON) Bit Name Description 7 CONFIG2 ‘1’: test of VDD threshold is switched off (latched) ‘0’: test of VDD threshold is switched on (r/w) 6 CONFIG1 ‘1’: lower threshold of VDD-monitoring is lifted (If CONFIG2 = 0 - test of switch-off path) (latched) ‘0’: upper threshold of VDD-monitoring is reduced (If CONFIG2 = 0 - test of switch-off path) (r/w) 5 CONFIG0 ‘1’: latch function for overvoltage at VDD is switched on (latched) ‘0’: latch function for overvoltage at VDD is switched off (r/w) 4 DIACLR2 if set = 0: all previous errors of DIA_REG2 are reset (not latched) if set = 1: no action (r/w) if read then always = 1 3 DIACLR1 if set = 0 then all latched errors of DIA_REG1 are to be transferred to the register DIA_REG2 and DIA_REG1 is reset. Exception is: if an undervoltage at pin VS is present, DIACLR1 will not have any effect. if set = 1: no action (not latched) if read then always = 1 (r) 2 STATUS2 Logic level at NABE (r) 1 STATUS1 ‘1’: no undervoltage at VDD (not latched) ‘0’: undervoltage at VDD (r) 0 STATUS0 ‘1’: no overvoltage at VDD ‘0’: overvoltage at VDD resp. state of overvoltage still stored (reset by CONFIG0 = ’0’) (r) Comment: overvoltage information (bit STATUS0 = 0) will not be reset by undervoltage at VS. Overvoltage will even be detected and stored (CONFIG0 = 1) during undervoltage at VS. The information will be reset if an internal (undervoltage at VDD) reset occurs or when CONFIG0 is set to 0 or via SPI reset (CONFIG_REG.RESET = 0). Remarks: Write-access is only possible for CONFIGx and DIACLRx. The bits STATUSx are not affected by a write-access to STATCON_REG, except indirectly by a change of CONFIGx. Any write access to STATCON_REG will take effect immediately. No re-enabling via switching (DIS to HIGH and then to LOW again) or (NABE via switching to Low and then to High again) is necessary. L9969x Functional description DS14029 - Rev 6 page 50/70 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |