| поискавой системы для электроныых деталей |
|
L9305 датащи(PDF) 19 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9305 датащи(HTML) 19 Page - STMicroelectronics |
|
19 / 107 page ![]() Table 10. Solenoid driver status in hardware mode EN_DR INx Driver Configuration Status Channel Status [1] [0] LOW X X X Driver Disabled, Off Diagnosis disabled and Masked HIGH HIGH X X HIGH LOW 0 0 HIGH LOW 0 1 Driver in Tristate, Off diagnosis can be switched on HIGH LOW 1 0 Driver ON in PWM mode,Off Diagnosis disabled and Masked HIGH LOW 1 1 Driver ON in Full ON mode,Off Diagnosis disabled and Masked Disabled Mode: Output drivers are disabled, no bias is present on the driver, off-state diagnostics are masked and cannot be enabled; LS clamp feature is inactive, thus, if an overvoltage occurs when driver is disabled, low side mos will not be protected Tristate Mode: Driver is supplied and kept in a tristate high impedance mode, off state diagnostics can be enabled PWM Mode: Output drivers are actively regulating load current as programmed, off state diagnostics are disabled. FULL_ON Mode: Output driver is driven to saturation and is kept on continuously until the mode is changed by the user or a fault occurs. Figure 9. Hardware control configuration INx VS_SOL_x LOADx GND_SOL_x EN_DR Driver Control SPI HS Current Sense LS Current Sense HS Driver LS Driver SPI Target current Switching freq. Control param. Dither GADG2709181150PS Upon completing channel configuration and set-up as summarized in Section 6: Current control drivers, the internal hardware control loop can then be configured for either fixed frequency or variable frequency current control (HW feedback Frequency Mode D[11] in CTRLCFG register). The current control method (HW mod/SW mode) is selectable using register CONFIGURATION1, D[2]. In addition to selecting the control method, the user must program the targeted load current and operating frequency. Load current is programmed through the Current Set Point Register (SETPOINT) and the operating frequency in the Control Configuration Register (CTRLCFG). Once the channel is enabled, the device begins to PWM control the load current for the targeted current value. The device can synchronize channel actuation by enabling all channels with a single SPI write operation. Actuation control can also be staggered 90 degrees when programmed for fixed frequency control using the Stagger Enable D[0] bit in SERVENA register. L9305 Current control drivers DS12774 - Rev 10 page 19/107 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |