18 / 66 page ![]() WM8804 Production Data w PD Rev 4.1 September 2007 18 SOFTWARE REGISTER RESET Writing to register 0000000 will reset the WM8804. This will reset all register bits to their default values. The WM8804 is powered down by default so writing to this register will power down the device. DEVICE ID AND REVISION IDENTIFICATION Registers 0,1 and 2 can be read to identify the device ID and IC revision number. Refer to Table 12 for details. REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION RESET N/A Writing to this register will apply a reset to the device. R00 RST/DEVID1 00h 7:0 DEVID1[7:0] 00000101 Reading from this register will return the second part of the device ID 00000101 = 0x05 R01 DEVID2 01h (read only) 7:0 DEVID2[7:0] 10001000 Reading from this register will return the first part of the device ID 10001000 = 0x88 R02 DEVREV 02h 3:0 DEVREV [3:0] N/A Reading from this register will return the device revision. 0x1 = revision 1 Table 12 Software Reset Register and Device ID HARDWARE CONTROL MODE The WM8804 can be operated in either software or hardware control modes. The method of control is determined by sampling the state of the SDIN pin during power up or hard reset. If SDIN is LOW during power up or hardware reset, the WM8804 will be switched into hardware control mode. PIN 0 1 SDIN Hardware control Mode Software control Mode Table 13 Hardware / Software Mode Configuration In hardware control mode the user has limited control over the configuration of the device. Most of the features will assume default values but some can be configured using external pins. When the device is configured in hardware control mode, all functions of the device are powered up. The clock and data recovery module requires a 12 MHz crystal derived clock reference as the default values for this module cannot be altered in hardware control mode. MASTER / SLAVE MODE SELECTION The WM8804 can be configured in either master or slave mode. In software control mode this is set by writing to AIF_MS in the AIFRX register. In hardware control mode this is controlled by sampling the SCLK pin on power up or hardware reset. PIN (HARDWARE MODE) REGISTER (SOFTWARE MODE) 0 1 SCLK AIF_MS Slave mode Master mode Table 14 Master / Slave Mode Configuration in Hardware Mode |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |