17 / 66 page ![]() Production Data WM8804 w PD Rev 4.1 September 2007 17 Multiple consecutive register writes can be performed in 2-wire control mode by setting the CONT bit high. This method allows the entire register map to be defined in a one continuous write operation. Figure 12 2-Wire Serial Control Interface Multi-Write The WM8804 has two possible device addresses, which can be selected using the CSB pin during hardware reset. CSB STATE DEVICE ADDRESS IN 2-WIRE MODE ADDRESS (X=R/W BIT) X=0 X= 1 Low 0111010x 0x7A 0x75 High 0111011x 0x76 0x77 Table 11 2-Wire Interface Address Selection 2-WIRE SERIAL CONTROL MODE -REGISTER READ-BACK The WM8804 allows read-back of certain registers in 2-wire mode. The protocol is similar to that used to write to the device. The controller will issue the device address followed by a write bit, the register index will then be passed to the WM8804. At this point the controller will issue a repeated start condition and resend the device address along with a read bit. The WM8804 will acknowledge this and the WM8804 will become a slave transmitter. The WM8804 will transmit the data from the indexed register on SDIN MSB first. When the controller receives the data it will not acknowledge receipt of the data indicating that it will resume master transmitter control of SDIN. The controller will then issue a stop command completing the read cycle. Figure 13 illustrates the read protocol. Figure 13 2-Wire Serial Control Interface Read (CONT=0) 2-WIRE SERIAL CONTROL MODE – CONTINUOUS READ-BACK As in 3-wire mode, there are two methods of reading back data: continuous and non-continuous read-back. Continuous read-back is selected by setting CONT to 1. In continuous read-back mode, the device will return the indexed register first followed by consecutive registers in increasing index order until the controller does not acknowledge the data then issues a stop sequence. This is shown in Figure 14 Figure 14 2-Wire Serial Interface Continuous Read-Back (CONT=1) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |