73 / 92 page ![]() Production Data WM8580 w PD Rev 4.0 February 2007 73 R40 GPO3 28 0 GPO6OP[3:0] GPO5OP[3:0] 001010100 R41 GPO4 29 0 GPO8OP[3:0] GPO70P[3:0] 001110110 R42 GPO5 2A 0 GPO10OP[3:0] GPO9OP[3:0] 010011000 R43 INTSTAT 2B Error Flag Interupt Status Register - R44 SPDRXCHAN 1 2C Channel Status Register 1 - R45 SPDRXCHAN 2 2D Channel Status Register 2 - R46 SPDRXCHAN 3 2E Channel Status Register 3 - R47 SPDRXCHAN 4 2F Channel Status Register 4 - R48 SPDRXCHAN 5 30 Channel Status Register 5 - R49 SPDSTAT 31 S/PDIF Status Register - R50 PWRDN 1 32 0 0 ALLDACPD 1 DACPD[2:0] ADCPD PWDN 001111110 R51 PWRDN 2 33 0 0 0 SPDIFRXD SPDIFTXD SPDIFPD PLLBPD PLLAPD OSCPD 000111110 R52 READBACK 34 0 0 0 0 READEN CONTREAD READMUX[2:0] 000000000 R53 RESET 35 RESET n/a REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION R0 PLLA 1/ DEVID1 00h 8:0 PLLA_K[8:0] 100100001 R1 PLLA 2/ DEVID2 01h 8:0 PLLA_K[17:9] 101111110 3:0 PLLA_K[21:18] 1101 Fractional (K) part of PLLA frequency ratio (R). Value K is one 22-digit binary number spread over registers R0, R1 and R2 as shown. Reading from these registers will return the device ID. R0 returns 10000101 = 80h R1 returns 10000000 = 85h Device ID readback is not possible in continuous readback mode (CONTREAD=1). R2 PLLA 3/ DEVREV 02h 7:4 PLLA_N[3:0] 0111 Integer (N) part of PLLA frequency ratio (R). Use values in the range 5 ≤ PLLA_N ≤ 13 as close as possible to 8. Reading from this register will return the device revision number. 0 PRESCALE_A 0 PLL Pre-scale Divider Select 0 = Divide by 1 (PLL input clock = oscillator clock) 1 = Divide by 2 (PLL input clock = oscillator clock ÷ 2) Note: PRESCALE_A must be set to the same value as PRESCALE_B in PLL S/PDIF receiver mode. 1 POSTSCALE_A 0 PLL Post-scale Divider Select PLL S/PDIF Receiver Mode POSTSCALE_A is used to configure a 256fs or 128fs PLLACLK, POSTSCALE_B is not used. Refer to Table 44. PLL User Mode Used in conjunction with the FREQMODE_x bits. Refer to Table 43. R3 PLLA 4 03h 4:3 FREQMODE_A[ 1:0] 10 PLL Output Divider Select PLL S/PDIF Receiver Mode FREQMODE_A is automatically controlled. FREQMODE_B is not used. PLL User Mode Used in conjunction with the POSTSCALE_x bits. Refer to Table 43. R4 PLLB 1 04h 8:0 PLLB_K[8:0] 100100001 Fractional (K) part of PLLB frequency ratio (R). Value K is one 22-digit binary number spread over registers R4, R5 and R6 as shown. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |