| поискавой системы для электроныых деталей |
|
AD5100EVAL датащи(PDF) 27 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD5100EVAL датащи(HTML) 27 Page - Analog Devices |
|
27 / 32 page ![]() Preliminary Technical Data AD5100 Rev. PrJ | Page 27 of 32 Programming Sequence S 0x5C A 0x01 A 0x8F A P Delay S 0x5D Comment Start Slave Addr ess + Write Ack Set V1MON OV Thres hold Ack OTP at setti ng 15 Ack Stop Wait for 30ms Start Slave Addr ess + Read Figure 24. Example of Executing OTP and a Successful Validation When all default registers have been programmed, the lock bit should be set. User programmed defaults won’t become active until the first power cycle after the lock bit is set. Programming the lock bit is done in exactly the same manner as all other registers. Temporary Over-Ride of Default Settings (Over-Ride Function) As stated previously in the register map section, even with the lock bit set, it is possible to temporarily over-ride the default values of any of the permanently programmable registers. To Over-Ride a permanent setting in a particular register, the following sequence should be used: 1. Set bit [3] in register 0x16 (Special Functions 1) 2. Write the desired temporary data to the register of choice While the Over-Ride bit is set in register 0x18, the user may over- ride any registers they wish by simply writing to them with new data. To revert an over-ridden register back to its default setting, the following sequence should be used: 1. Clear bit [3] in register 0x16 2. Write a dummy byte to the register of choice Clearing the Over-Ride bit in register 0x18 does not cause all over- ridden registers to revert back to their defaults at the same time. For example, imagine the user had over-ridden registers 0x01, 0x02 & 0x03. If the user now cleared the Over-Ride bit in register 0x16 and wrote a dummy byte to register 0x01, it would revert back to its default value. However registers 0x02 & 0x03 would still contain their Over-Ride data. To revert both registers back to their defaults, the user must write dummy data to each register individually. Power cycling the AD5100 will also revert all registers back to their programmed defaults. Controlling the AD5100 There are two ways to control the AD5100. Users can apply the AD5100 evaluation software for one time programming the devices in the factory without ever reprogramming the parts in the fields. They can also design or make use of the on-board I2C controllers for programming the AD5100. The later is necessary for any dynamic or field programming applications. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |