| поискавой системы для электроныых деталей |
|
AD5100EVAL датащи(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD5100EVAL датащи(HTML) 19 Page - Analog Devices |
|
19 / 32 page ![]() Preliminary Technical Data AD5100 Rev. PrJ | Page 19 of 32 Power Requirements Internal Power The AD5100 internal power VREG is derived from V1MON and V2MON is used to turn AD5100 on and off with a different behavior depending on the V2MON monitoring mode selection. By default, in the V2MON level sensitive mode, the AD5100 turns on when the voltage at V2MON rises above the logic threshold V2MON_ON, When V2MON falls below the logic threshold V2MON_OFF, AD5100 will trun off 2 seconds after SHDN is deasserted. Note that AD5100 requries 5 us to start up and that V1MON must be applied before V2MON. The extension of the AD5100 turn-off attempts to allow the system to complete any housekeeping tasks before the system is powered off. Figure 17 shows the defaulted V2MON and VREG waveforms. V 2MON 2.2V t GLITCH t VREG_On_Delay 6V < V 1MON < 30V * Programmable t VREG_Off_Delay V REG t 2SD_HOLD * SHDN V 2MON_ON * V 2MON_OFF * t 2SD_HOLD * t 2SD_DELAY * t VREG_Off_Delay V 2MON_OFF * V 2MON_ON * t 2SD_DELAY * t 2SD_DELAY * V 2MON 2.2V t GLITCH t VREG_On_Delay 6V < V 1MON < 30V * Programmable t VREG_Off_Delay V REG t 2SD_HOLD * SHDN V 2MON_ON * V 2MON_OFF * t 2SD_HOLD * t 2SD_DELAY * t VREG_Off_Delay V 2MON_OFF * V 2MON_ON * t 2SD_DELAY * t 2SD_DELAY * Figure 17. Internal Power VREG versus V2MON Timing Diagrams (Default) If the Pulse-Sensitive V2MON Mode is selected instead, the AD5100 will not turn off when V2MON returns to a logic low. In this mode, once the part has been powered on, it can only be power-down by an I2C power down instruction or by eliminating the supply on V1MON pin. This feature is for the applications that use a wake up signal. VOTP A 6V supply voltage is needed only during OTP fuse programming. This voltage should be provided by an external source during factory programming and should have 6V/200mA driving capability. The OTP programming duration depends on the numbers of programming fuses with maximum duration of 10ms. VOTP is not required for normal operation. The VOTP has dual functions, it is used for programming the non-volatile memory fuse arrays as well as serving as a compensation network for internal power stability. As a result, a bypass capacitor must be connected at VOTP pin at all times. A low ESR 10uF tantalum capacitor is recommended. Figure 18. Power Supply Requirement AD5100 achieves the OTP function through blowing internal fuses. Users should always apply the 6 V one-time program voltage requirement at the first fuse programming attempt. Failure to comply with this requirement may lead to a change in the fuse structures, rendering programming inoperable. Care should be taken when SCL and SDA are driven from a low voltage logic driver. AD5100 V1MON 6V - 30V 6V VOTP APPLY FOR OTP ONLY C2 10 μF V2MON 3V - 30V |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |