13 / 32 page ![]() Preliminary Technical Data AD5100 Rev. PrJ | Page 13 of 32 V3MON V3MON is a low-voltage monitoring input that controls the RESET function of an external device. V3MON monitors inputs from 2.5V to 5.5V. It has an 8-step programmable reset threshold with an 8-step 0.1ms-200ms reset hold time. The reset hold time means that the reset of the external device is held until the programmed-time is reached. The V3MON and reset timing diagrams are shown in Figure 8. The range of thresholds is shown in Table 5a and the programming code of the selected-threshold is found in Table 5b. The defaulted monitoring threshold is 4.36V. Similarly, the range of reset hold time is shown in Tables 6a and the programming code of the selected-timing is found in Table 6b. The defaulted reset hold time is 200ms. V 3MON t GLITCH t RS_HOLD* RESET V 3MON t RS_HOLD* t RS_DELAY t RS_DELAY * Programmable V 3MON t GLITCH t RS_HOLD* RESET V 3MON t RS_HOLD* t RS_DELAY t RS_DELAY * Programmable Figure 8. V3MON RESET Timing Diagrams The V3MON pin is monitored by a comparator to detect an under-voltage condition. It is designed with 1.5% hysteresis. When the V3MON input drops below the programmed UV threshold, the comparator will become active immediately, indicating a UV condition has occurred. Due to hysteresis, the V3MON input must be brought above the programmed UV threshold by 1.5% before the comparator will be in-active, indicating the UV condition has gone away, see Figure 9. The V3MON comparator is used (in conjunction with a hold timer) to control the RESET pin. V3MON exhibits typical input resistance of 50KΩ that users should account the loading effect. The MR input has an internal resistor pull-up toV3MON. The RESET output are push-pull configured between V3MON and GND. V 3MON V 3MON_UV Hysteresis UV Comparator In-Active UV Comparator In-Active V 3MON V 3MON_UV Hysteresis UV Comparator In-Active UV Comparator In-Active Figure 9. V3MON Hysteresis. The default V3MON threshold is 4.36V. User should refer to Table 5b if they want to program different setting. V4MON V4MON is the lowest voltage monitoring input that controls the RESET function of an external device or provides a comparator output, V4OUT. V4MON monitors input from 0.9V to 3.3V. It has an 8-step programmable reset threshold with an 8-step 0.1ms to 200ms reset hold time. The V4MON, reset, and V4OUT timing diagrams are shown in Figure 10. The range of thresholds is shown in Table 5a and the programming code of the selected-threshold is found in Tables 5b. The defaulted monitoring threshold is Disabled. Similarly, the range of reset hold time is shown in Tables 6a and the programming code of the selected-timing is found in Table 6b. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |