| поискавой системы для электроныых деталей |
|
AM79C901AVCT датащи(PDF) 28 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C901AVCT датащи(HTML) 28 Page - Advanced Micro Devices |
|
28 / 90 page ![]() 28 Am79C901A PR ELI M IN AR Y Figure 13. Normal Operation MII-Compatible Interface for HomePNA PHY The control and data signals that are utilized in the MII- compatible interface of the 1 Mbps HomePNA PHY function in an manner that is identical to that as defined in the 802.3u specification. The signals RX_CLK and TX_CLK function in a slightly different manner in that they operate at a reduced data rate and that these clock signals do not run at a constant rate due to the RLL25™ encoding scheme. See Table 4. Table 4. MII-Compatible Timing Note: During the AID interval, TX_CLK and RX_CLK stop for up to 140 µs. Figure 14 and Figure 15 represent the signal relation- ships when the MII-compatible data interface is utilized. The signals TX_CLK and RX_CLK will toggle at a rate of approximately 428 kHz during idle time. When the TX_EN signal is asserted to indicate the beginning of a transmission, the clock rate will enter the preamble phase. Once the SFD has been detected and the HomePNA PHY has begun the transmission of the HomePNA header, the clock enters the data phase. When the TX_EN signal is deasserted to indicate the ending of a transmission, TX_CLK is halted until the RXDATA path detects the end of the packet. At this time, the clock rate is increased to the IPG data rate for 96 bit times and then returns to the Idle state. MII-Compliant Interface for 10BASE-T PHY The MII interface is fully IEEE 802.3u-compliant when the 10BASE-T PHY is selected. The management in- terface specified in Clause 22 of the IEEE 802.3u stan- dard provides for a simple two wire, serial interface to connect a management entity and a managed PHY for the purpose of controlling the PHY and gathering sta- tus information. The two lines are Management Data Input/Output (MDIO) and Management Data Clock (MDC). A station management entity, which is attached to multiple PHY entities, must have prior knowledge of the appropriate PHY address for each PHY entity. The management interface physically transports man- agement information across the MII. The information is encapsulated in a frame format as specified in Clause 22 of the IEEE 802.3u standard and is shown in Table 5. Table 5. MII Control Frame Format 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 30 31 32 Op Codes Address Data In Data Out Error Code = 0 SCLK CS SDI SDO 22304B-15 Condition CLK Period CLK Frequency Idle (excluding IPG time) 2333.34 ns 428.6 kHz Preamble (first 64 bits of TX MAC frame) 933.33 ns 1.07 MHz Data (throughout the data phase) 400 ns - 40 µs250 kHz avg. IPG (96 bit times following CRS ↓) 933.33 ns 1.07 MHz PRE ST OP PHYADD REGADD TA DATA IDLE READ 1...1 01 10 AAAAA RRRRR Z0 D15………D0 Z WRITE 1...1 01 01 AAAAA RRRRR 10 D15………D0 Z |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |