| поискавой системы для электроныых деталей |
|
ADF7021 датащи(PDF) 24 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADF7021 датащи(HTML) 24 Page - Analog Devices |
|
24 / 44 page ![]() ADF7021 Preliminary Technical Data Rev. PrI | Page 24 of 44 As with the external Rx/Tx switch, an additional LPF or BPF could be required to suppress harmonics in the transmit spectrum or to improve the resilience of the receiver against out-of-band interferers. TRANSMIT PROTOCOL AND CODING CONSIDERATIONS PREAMBLE SYNC WORD ID FIELD DATA FIELD CRC Figure 25. Typical Format of a Transmit Protocol A dc-free preamble pattern is recommended for FSK demodula- tion. The recommended preamble pattern is a dc-free pattern such as a 10101010 … pattern. Preamble patterns with longer run-length constraints such as 11001100… can also be used. However, this results in a longer synchronization time of the received bit stream in the receiver. Manchester coding can be used for the entire transmit protocol. However, the remaining fields that follow the preamble header do not have to use dc-free coding. For these fields, the ADF7021 can accommodate coding schemes with a run length of up to 6 bits without any performance degradation. If longer run-length coding must be supported, the ADF7021 has several other features that can be activated. These involve a range of programmable options that allow the envelope detector output to be frozen after preamble acquisition. DEVICE PROGRAMMING AFTER INITIAL POWER-UP Table 13 lists the minimum number of writes needed to set up the ADF7021 in either Tx or Rx mode after CE is brought high. Additional registers can also be written to tailor the part to a particular application, such as setting up sync byte detection or enabling AFC. When going from Tx to Rx or vice versa, the user needs to write only to Register 1 to alter the LO by 100 kHz and to toggle the Tx/Rx bit. Table 13. Minimum Register Writes Required for Tx/Rx Setup Mode Registers Tx Reg 0 Reg 1 Reg 2 Reg 3 Rx Reg 0 Reg 1 Reg 3 Reg 4 Reg 5 Tx <-> Rx Reg 0 Figure 26 and Figure 27 show the recommended programming sequence and associated timing for power-up from standby mode. 2.0mA 3.65mA 12mA TIME REG. READY t1 WR1 t3 VCO t4 WR3 t5 WR6 t6 WR5 t7 19mA TO 22mA tOFF tON XTAL t0 WR0 t9 WR4 t10 AGC/ RSSI t11 CDR t12 AFC t13 RxDATA t14 t2 t8 Figure 26. Rx Programming Sequence and Timing Diagram |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |