30 / 55 page ![]() 25CSM04 DS20005817D-page 30 2019-2022 Microchip Technology Inc. and its subsidiares 9.1.1 READING THE FACTORY-PROGRAMMED 128-BIT SERIAL NUMBER The Security register contains a factory-programmed, globally unique, read-only 128-bit serial number. This serial number is unique across all varieties of Microchip CS series EEPROM and it is located in the lower 16 bytes of the Security register (bytes 0h-Fh). Reading the serial number is accomplished in the same way as the reading of any other data in the Security register. 9.2 Writing to the Security Register Executing a write sequence to the Security register is identical to the EEPROM as described in Section 8.1.1 “Byte Write” and Section 8.1.2 “Page Write” with the exception that the WREX (82h) instruction is used and A10 must be a logic ‘0’ and A8 must be a logic ‘1’ in order to write the user-programmable lockable ID page. In Legacy Write Protection mode, the Security register is write-protected when the BP [1:0] bits (byte 0, bits 3-2) of the STATUS register = 11. There is no dependency on the WPEN bit (byte 0, bit 7) of the STATUS register or the WP pin. The user-programmable lockable ID page of the Security register can also be permanently locked such that its contents also become read-only. This is accomplished with LOCK instruction. Determining if the device has previously been locked can be determined with the CHLK instruction. If the Security register is locked, any subsequent WREX instructions will be ignored. 9.2.1 LOCKING THE SECURITY REGISTER The upper 256 bytes of the Security register are shipped by Microchip in a user-programmable state. Once the desired data is written, the user-programmable lockable ID page of the Security register can be permanently write-protected with the LOCK instruction. The LOCK instruction is irreversible and will permanently prevent all future write sequences to the upper 256 bytes of the Security register on the 25CSM04, thereby rendering the entire 512-byte Security register read-only. The LOCK instruction emulates a write sequence in that a WREN instruction must first be sent to set the WEL bit in the STATUS register to logic ‘1’. As shown in Figure 9-4, the LOCK (82h) instruction is clocked in on the SI line, followed by a dummy address where bits A23 through A0 are “don’t care” bits with the exception that bit A10 must be set to ‘1’. Finally, a confirmation data byte of xxxxxx1xb is sent and the self-timed internal write cycle will begin once the CS pin is driven high. Note: To ensure a unique number, the 128-bit serial number must be read from the starting address. Additionally, the entire serial number must be read to realize a completely unique value. Note: If the CS pin is deasserted at somewhere other than the end of an 8-bit byte boundary, the sequence will be aborted and no write cycle will take place. Note: The LOCK instruction will be ignored if the WPEN bit (byte 0, bit 7) of the STATUS register is set to a logic ‘1’ and the WP pin is asserted. Note: Once the Security register has been locked, it is not possible to unlock it. Note: If the CS pin is deasserted before the end of the 40-bit sequence, the sequence will be aborted and no write cycle will take place. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |