49 / 81 page ![]() Datasheet 49 Rev. 1.0 2017-11-23 TLE75620-EST SPIDER+ 12V Diagnosis Due to the fact that Output Status Monitor checks the voltage level at the outputs in real time, for Open Load in OFF diagnostic it is necessary to synchronize the reading of DIAG_OSM register with the OFF state of the channels. Figure 25, Figure 26 and Figure 27 shows how Output Status Monitor is implemented at concept level. Figure 25 Output Status Monitor - concept (auto-configurable channel as High-Side) Figure 26 Output Status Monitor - concept (Auto-configurable channel as Low-Side) OutStatMon_XS.emf Auto-configurable Channel (as high -side) GND VS VOUT_Sn OUT_Dn OUT_Sn VDS ROL I OL IOL VOUT_S(OL) DIAG_OSM.OUTn VOUT_S > VOUT_S(OL) DIAG_OSM.OUTn = „1" OutStatMon_XS_LS.emf Auto-configurable Channel (as low-side) GND VS OUT_Dn OUT_Sn VDS ROL IOL IOL VDS(OL) VDS < VDS(OL) DIAG_OSM.OUTn = „1" DIAG_OSM.OUTn |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|