| поискавой системы для электроныых деталей |
|
SCD1284 датащи(PDF) 56 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
SCD1284 датащи(HTML) 56 Page - Intel Corporation |
|
56 / 176 page ![]() CD1284 — IEEE 1284-Compatible Parallel Interface Controller 56 Datasheet As previously discussed, the send special character command is preemptive to data currently in the transmit FIFO. The XOFF character is transmitted immediately after the current character and the character in the Transmitter Holding register are sent (a maximum delay of two character times). When the CPU is again ready to start receiving characters, the XON character is sent by another send special character command. At this time, the CD1284 is issued the command to send the character programmed in SCHR1. Send special character commands override any flow-control by a remote of the CD1284. For example, even if the CD1284 transmitter is shut off by the remote, it can still send flow control characters. The current state of the flow-control condition is always made available to the CPU through the CCSR. In addition to the enabled/disabled status of the receiver and transmitter, the CCSR displays the flow-control status. Two bits in the CCSR pertain to receiver flow control, RxFloff and RxFlon. Whenever the CPU issues the send special character 2 (send XOFF) command, the CD1284 sets the RxFloff bit, indicating a request for the remote to stop transmission. When the CPU issues the send special character 1 (send XON) command, RxFlon is set and RxFloff reset. RxFlon remains set until the first character is received after XON is transmitted. Table 15 shows the bit encoding for RxFloff and RxFlon. RxFloff and RxFlon are cleared whenever the receiver is disabled or enabled, regardless of the state of flow control when the disable/enable occurred. Note: Regardless of the current state of RxFloff, the CD1284 continues to receive characters. If the remote ignores or is slow to respond to the XOFF character, there an overrun condition can occur. 5.6.2.1 Transmitter In-Band Flow Control The CD1284 can automatically flow control its own transmitter when it receives the XON and XOFF characters, as programmed in SCHR1 and SCHR2. There are control bits in COR2 and COR3 to enable or disable various aspects of automatic flow control. Special-character detection must be enabled through the SCD12 bit (COR3[4]) for flow-control characters to be acted upon. When SCD12 is set, the CD1284 scans received characters for a match with one of the special characters programmed in SCHR1–SCHR2. Table 15. CCSR[6:5] Encoding RxFloff RxFlon Encoded Status 00 Transmission resumes, the receiver is enabled/disabled, or receiver is in the default reset state. 01 XON is sent, but transmission has not restarted. 1 0 XOFF was sent. 1 1 Not used. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |