| поискавой системы для электроныых деталей |
|
AD6636PCB датащи(PDF) 41 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD6636PCB датащи(HTML) 41 Page - Analog Devices |
|
41 / 72 page ![]() AD6636 Rev. 0 | Page 41 of 72 operation in the logarithmic domain. The rms samples obtained are subtracted from the request signal level R specified in the AGC desired level register, leaving an error term to be processed by the loop filter, G(z). The user sets this programmable request signal level R accord- ing to the output signal level that is desired. The request signal level R is programmable from −0 dB to −23.99 dB in steps of 0.094 dB. The request signal level should also compensate for errors, if any, due to the CIC scaling, as explained previously in this section. Therefore, the request signal level is offset by the amount of error induced in CIC, given by Offset = 10 × log(MCIC × Navg) − SCIC × 3.01 dB where Offset is in dB. Continuing the previous example, this offset is given by Offset = 72.24 − 69.54 = 2.7 dB So the request signal level is given by dBFS 094 . 0 094 . 0 ) ( × ⎥⎦ ⎤ ⎢⎣ ⎡ − − = Offset DSL ceil R where: R is the request signal level. DSL (desired signal level) is the output signal level that the user desires. Therefore, in the previous example, if the desired signal level is −13.8 dB, the request level R is programmed to be −16.54 dB, compensating for the offset. This request signal level is programmed in the 8-bit AGC desired level register. This register has a floating-point represen- tation, where the 2 MSBs are exponent bits and the 6 LSBs are mantissa bits. The exponent is in steps of 6.02 dB, and the mantissa is in steps of 0.094 dB. For example, a value 10’100101 represents 2 × 6.02 + 37 × 0.094 = 15.518 dB. The AGC provides a programmable second-order loop filter. The programmable parameters gain 1 (K1), gain 2 (K2), error threshold E, and pole P completely define the loop filter characteristics. The error term after subtracting the request signal level is processed by the loop filter, G(z). The open loop poles of the second-order loop filter are 1 and P, respectively. The loop filter parameters, pole P and gain K, allow the adjustment of the filter time constant that determines the window for calculating the peak-to-average ratio. Depending on the value of the error term that is obtained after subtracting the request signal level from the actual signal level, either gain value, K1 or K2, is used. If the error is less than the programmable threshold E, K1 or K2 is used. This allows a fast loop when the error term is high (large convergence steps required) and a slower loop function when error term is smaller (almost converged). The open-loop gain used in the second-order loop G(z) is given by one of the following equations: K = K1, if Error < Error Threshold K = K2, if Error > Error Threshold The open-loop transfer function for the filter, including the gain parameter, is () () 2 1 1 1 1 − − − + + − = Pz z P Kz z G If the AGC is properly configured in terms of offset in request level, then there are no gains in the AGC loop except for the filter gain K. Under these circumstances, a closed-loop expression for the AGC loop is given by () () () () 2 1 1 1 1 1 − − − + − − + = + = Pz z P K Kz z G z G z Gclosed The gain parameters K1, K2, and pole P are programmable through AGC loop gain 1, 2, and AGC pole location registers from 0 to 0.996 in steps of 0.0039 using 8-bit representation. For example, 1000 1001 represent (137/256 = 0.535156). The error threshold value is programmable between 0 dB and 96.3 dB in steps of 0.024 dB. This value is programmed in the 12-bit AGC error threshold register, using floating-point representation. It consists of four exponent bits and eight mantissa bits. Exponent bits are in steps of 6.02 dB and mantissa bits are in steps of 0.024 dB. For example, 0111’10001001 represents 7 × 6.02 + 137 × 0.024 = 45.428 dB. The user defines the open-loop pole P and gain K, which also directly impact the placement of the closed-loop poles and filter characteristics. These closed-loop poles, P1, P2, are the roots of the denominator of the previous closed-loop transfer function and are given by 2 4 ) 1 ( ) 1 ( , 2 P K P K P P P 2 1 − − + + − + = Typically, the AGC loop performance is defined in terms of its time constant or settling time. In this case, the closed-loop poles should be set to meet the time constants required by the AGC loop. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |