| поискавой системы для электроныых деталей |
|
UCS1002-2 датащи(PDF) 113 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS1002-2 датащи(HTML) 113 Page - Microchip Technology |
|
113 / 114 page ![]() Programmable USB Port Power Controller with Charger Emulation Datasheet SMSC UCS1002 113 Revision 1.4 (07-16-13) DATASHEET Table 3.3, "Electrical Specifications" Changed tDET_CHARGE from 400 ms to 800 ms typ and changed condition from CBUS = 220 µF to CBUS = 500 µF max. VS Leakage Current changed from 0.8 µA typical to 2.2 µA. Changed IBD_1 and IBD_2 from TBD typ to 0 µA typ and from 1.5 µA max to 2 µA max Changed ITST to ITEST and changed typ from 165 to 190 mA. Changed tON_PSW from 3 ms to 0.75 ms typical and tOFF_PSW_INA from 1 ms to 0.75 ms typical. Spec changed for tHD:DAT. 0 µs min has condition when transmitting to master. New row added with 0.3 µs min with condition when receiving from master. New characteristic: Bus Free Time Stop to Start, Start Setup Time, Hold Time, Setup Time, Clock Low Period, Clock High Period Data Fall Time -> Clock / Data Fall Time Data Rise Time -> Clock / Data Rise Time Table 3.4, "ESD Ratings"Section 3.1 Charged Device Model: changed from 200 V to 500 V Note 5.1 Added note: In order to transition from Active state Data Pass- through mode into Sleep with these settings, change the M1, M2, and EM_EN pins before changing the PWR_EN pin. Table 5.1, "Power States Control Settings", Section 5.1.2, "Sleep State Operation", Section 6.1, "USB High- speed Data Switch" The high-speed switch is open in Sleep. Section 5.2.2, "VS Source Voltage" Added. Cover, Section 9.11.3, "Legacy 1, 3, 4, and 6 Charger Emulation Profiles" Legacy 6 profile has been defined. Revision 1.1 (11-21-11) cont. Section 9.4, "Data Pass- through (No Charger Emulation)" Data Pass-through persists until M1, M2, or EM_EN controls are changed. It is no longer affected by PWR_EN. Added application note: When the M1, M2, and EM_EN controls are set to ‘0’, ‘1’, ‘0’ or to ‘1’, ‘1’, ‘0’ respectively, Data Pass- through mode will persist if the PWR_EN control is disabled; however, the UCS1002 will draw more current. To leave Data Pass-through mode, the PWR_EN control must be enabled before the M1, M2, and EM_EN controls are changed to the desired mode. Section 9.6, "BC1.2 CDP" BC1.2 CDP mode uses constant current limiting. Added application note: BC1.2 compliance testing may require the S0 control to be set to ‘0’ (Attach and Removal Detection feature disabled) while testing is in progress. Added application note: When the UCSX100X is in BC1.2 CDP mode and the Attach and Removal Detection feature is enabled, if a power thief, such as a USB light or fan, attaches but does not assert DP, a Removal event will not occur when the portable device is removed. However, if a standard USB device is subsequently attached, Removal Detection will again be fully functional. As well, if PWR_EN is cycled or M1, M2, and / or EM_EN change state, a Removal event will occur and Attach Detection will be reactivated. Table 13.1 Customer Revision History (continued) REVISION LEVEL & DATE SECTION/FIGURE/ENTRY CORRECTION |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |