| поискавой системы для электроныых деталей |
|
UCS1002-2 датащи(PDF) 43 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
UCS1002-2 датащи(HTML) 43 Page - Microchip Technology |
|
43 / 114 page ![]() Programmable USB Port Power Controller with Charger Emulation Datasheet SMSC UCS1002 43 Revision 1.4 (07-16-13) DATASHEET 5.1.5 Error State Operation The UCS1002 will enter the Error state from the Active state when any of the following events are detected: 1. The maximum allowable internal die temperature (TTSD) has been exceeded (see Section 7.3.1.2). 2. An over-current condition has been detected (see Section 7.2.1). 3. An under-voltage condition on VBUS has been detected (see Section 5.2.5). 4. A back-drive condition has been detected (see Section 5.2.3). 5. A discharge error has been detected (see Section 7.4). 6. An over-voltage condition on the VS pins. The UCS1002 will enter the Error state from the Detect state when a back-drive condition has been detected or when the maximum allowable internal die temperature has been exceeded. The UCS1002 will enter the Error state from the Sleep state when a back-drive condition has been detected. When the UCS1002 enters the Error state, the port power switch, the VBUS bypass switch, the high- speed switch are turned off, and the ALERT# pin is asserted (by default). They will remain off while in this power state. The UCS1002 will leave this state as determined by the fault handling selection (see Section 7.6, "Fault Handling Mechanism"). When using the Latch fault handler and the user has re-activated the device by clearing the ERR bit (see Section 10.3, "Status Registers"), or toggling the PWR_EN control, the UCS1002 will check that all of the error conditions have been removed. If using Auto-recovery fault handler, after the tCYCLE time period, the UCS1002 will check that all of the error conditions have been removed. If all of the error conditions have been removed, the UCS1002 will return to the Active state or Detect state, as applicable. Returning to the Active state will cause the UCS1002 to restart the selected mode (see Section 9.2, "Active Mode Selection"). If the device is in the Error state and a Removal Detection event occurs, it will check the error conditions and then return to the power state defined by the PWR_EN, M1, M2, EM_EN, and S0 controls. 5.2 Supply Voltages 5.2.1 VDD Supply Voltage The UCS1002 requires 4.5 V to 5.5 V present on the VDD pin for core device functionality.Core device functionality consists of maintaining register states, wake-up upon SMBus / I2C query, and Attach Detection. 5.2.2 VS Source Voltage VS can be a separate supply and can be greater than VDD to accommodate high current applications in which current path resistances result in unacceptable voltage drops that may prevent optimal charging of some portable devices. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |