53 / 114 page ![]() Programmable USB Port Power Controller with Charger Emulation Datasheet SMSC UCS1002 53 Revision 1.4 (07-16-13) DATASHEET 7.4 VBUS Discharge The UCS1002 will discharge VBUS through an internal 100 Ω resistor when at least one of the following conditions occurs: The PWR_EN control is disabled (triggered on the inactive edge of the PWR_EN control). A portable device Removal Detection event is flagged. The VS voltage drops below a specified threshold (VS_UVLO) that causes the port power switch to be disabled. When commanded into the Sleep power state via the EM_EN, M1, and M2 controls. Before each charger emulation profile is applied. Upon recovery from the Error state. When commanded via the SMBus (see Section 10.4, "Configuration Registers") in the Active state.Any time that the port power switch is activated after the VBUS bypass switch has been on (i.e., whenever VBUS voltage transitions from being driven from VDD to being driven from VS, such as going from Detect to Active power state). Any time that the VBUS bypass switch is activated after the port power switch has been on (i.e., going from Active to Detect power state). When the VBUS discharge circuitry is activated, at the end of the tDISCHARGE time, the UCS1002 will confirm that VBUS was discharged. If the VBUS voltage is not below the VTEST level, a discharge error will be flagged (by setting the DISCHARGE_ERR status bit) and the UCS1002 will enter the Error state. 7.5 Battery Full Delivery of bus current to a portable device can be rationed by the UCS1002. When this functionality is enabled, the host system must provide the UCS1002 with an accumulated charge maximum limit (in milliampere-hours). The charge rationing functionality works only in the Active power state. It continuously monitors the current delivered as well as the time elapsed since the mode was activated (or since the data was updated). This information is compiled to generate a charge-rationing number that is checked against the host limit. Once the programmed current-rationing limit has been reached, the UCS1002 will take action as determined by the RATION_BEH bits as described in Table 7.1. Note that this does not cause the device to enter the Error state. Once the charge rationing circuitry has reached the programmed threshold, the UCS1002 will maintain the desired behavior until charge rationing is reset. Once charge rationing has been reset or disabled, the UCS1002 will recover as shown in Table 7.2. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |