| поискавой системы для электроныых деталей |
|
5000 датащи(PDF) 101 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
5000 датащи(HTML) 101 Page - Intel Corporation |
|
101 / 104 page ![]() Dual-Core Intel® Xeon® Processor 5000 Series Datasheet 101 Boxed Processor Specifications 8.3.2.1 1U Passive/2U Active Combination Heat Sink Solution (1U Rack Passive) In the 1U configuration it is assumed that a chassis duct will be implemented to provide sufficient airflow to pass through the heat sink fins. Currently the actual airflow target is within the range of 15-27 CFM. The duct should be designed as precisely as possible and should not allow any air to bypass the heat sink (0” bypass) and a back pressure of 0.38 in. H2O. It is assumed that a 40°C TLA is met. This requires a superior chassis design to limit the TRISE at or below 5°C with an external ambient temperature of 35°C. Following these guidelines will allow the designer to meet Thermal Profile B and conform to the thermal requirements of the processor. 8.3.2.2 1U Passive/2U Active Combination Heat Sink Solution (Pedestal Active) The active configuration of the combination solution is designed to help pedestal chassis users to meet the thermal processor requirements without the use of chassis ducting. It may be still be necessary to implement some form of chassis air guide or air duct to meet the TLA temperature of 40°C depending on the pedestal chassis layout. Also, while the active thermal solution is designed to mechanically fit into a 2U volumetric, it may require additional space at the top of the thermal solution to allow sufficient airflow into the heat sink fan. Therefore, additional design criteria may need to be considered if this thermal solution is used in a 2U rack mount chassis, or in a chassis that has drive bay obstructions above the inlet to the fan heat sink. Use of the active configuration in rackmount chassis is not recommended. It is recommended that the ambient air temperature outside of the chassis be kept at or below 35°C. The air passing directly over the processor thermal solution should not be preheated by other system components. Meeting the processor’s temperature specification is the responsibility of the system integrator. 8.3.2.3 2U Passive Heat Sink Solution (2U+ Rack or Pedestal) A chassis duct is required for the 2U passive heat sink. In this configuration the thermal profile (see Section 6) should be followed by supplying 27 CFM of airflow through the fins of the heat sink with a 0” or no duct bypass and a back pressure of 0.182 in. H2O. The TLA temperature of 40°C should be met. This may require the use of superior design techniques to keep TRISE at or below 5°C based on an ambient external temperature of 35°C. 8.4 Boxed Processor Contents A direct chassis attach method must be used to avoid problems related to shock and vibration, due to the weight of the thermal solution required to cool the processor. The board must not bend beyond specification in order to avoid damage. The boxed processor contains the components necessary to solve both issues. The boxed processor will include the following items: • Dual-Core Intel Xeon Processor 5000 series • Unattached Heat Sink Solution • 4 screws, 4 springs, and 4 heat sink standoffs (all captive to the heat sink) • Thermal Interface Material (pre-applied on heat sink) • Installation Manual •Intel Branding Logo |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |