AD5522JSVDZ датащи(PDF) 55 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD5522JSVDZ датащи(HTML) 55 Page - Analog Devices |
|
55 / 60 page ![]() AD5522 Rev. A | Page 55 of 60 APPLICATIONS INFORMATION POWER-ON DEFAULT The power-on default for all DAC channels is that the contents of each M register are set to full scale (0xFFFF), and the contents of each C register are set to midscale (0x8000). The contents of the DAC X1 registers at power-on are listed in Table 35. The power-on default for the alarm status register is 0xFFFFF0, and the power-on default for the comparator status register is 0x400000. The power-on default values of the PMU register and the system control register are shown in Table 36 and Table 37. SETTING UP THE DEVICE ON POWER-ON On power-on, default conditions are recalled from the power- on reset register to ensure that each PMU and DAC channel is powered up in a known condition. To operate the device, the user must follow these steps: 1. Configure the device by writing to the system control register to set up different functions as required. 2. Calibrate the device to trim out errors, and load the required calibration values to the gain (M) and offset (C) registers. Load codes to each DAC input (X1) register. When X1 values are loaded to the individual DACs, the calibration engine calculates the appropriate X2 value and stores it, ready for the PMU address to call it. 3. Load the required PMU channel with the required force mode, current range, and so on. Loading the PMU channel configures the switches around the force amplifier, measure function, clamps, and comparators, and also acts as a load signal for the DACs, loading the DAC register with the appropriate stored X2 value. 4. Because the voltage and current ranges have individual DAC registers associated with them, each PMU register mode of operation calls a particular X2 register. Therefore, only updates (that is, changes to the X1 register) to DACs associated with the selected mode of operation are reflected in the output of the PMU. If there is a change to the X1 value associated with a different PMU mode of operation, this X1 value and its M and C coefficients are used to calculate a corresponding X2 value, which is stored in the correct X2 register, but this value is not loaded to the DAC. Table 35. Default Contents of DAC Registers at Power-On DAC Register Default Value Offset DAC 0xA492 FIN DAC 0x8000 CLL DAC 0x0000 CLH DAC 0xFFFF CPL DAC 0x0000 CPH DAC 0xFFFF Table 36. Power-On Default for System Control Register Bit Bit Name Default Value 21 (MSB) CL3 0 20 CL2 0 19 CL1 0 18 CL0 0 17 CPOLH3 0 16 CPOLH2 0 15 CPOLH1 0 14 CPOLH0 0 13 CPBIASEN 0 12 DUTGND/CH 0 11 GUARD ALM 0 10 CLAMP ALM 0 9 INT10K 0 8 GUARD EN 0 7 GAIN1 0 6 GAIN0 0 5 TMP ENABLE 1 4 TMP1 0 3 TMP0 0 2 LATCHED 0 1 Unused data bit 0 0 (LSB) Unused data bit 0 Table 37. Power-On Default for PMU Register Bit Bit Name Default Value 21 (MSB) CH EN 0 20 FORCE1 0 19 FORCE0 0 18 Reserved 0 17 C2 0 16 C1 1 15 C0 1 14 MEAS1 1 13 MEAS0 1 12 FIN 0 11 SF0 0 10 SS0 0 9 CL 0 8 CPOLH 0 7 COMPARE V/I 0 6 LTMPALM 1 5 TMPALM 1 4 Unused data bit 0 3 Unused data bit 0 2 Unused data bit 0 1 Unused data bit 0 0 (LSB) Unused data bit 0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |