32 / 56 page ![]() Reference:CMV300-datasheet-v2.11 CMV300 Datasheet Page 30 of 54 © 2016 CMOSIS bvba Register name Register address Default value Description of the value Nr_slopes 54 1 The value in this register defines the number of slopes (min=1, max=3). Vtfl2 113[6:0] 64 The value in this register defines the Vtfl2 voltage (DAC setting) of kneepoint 1. Bit[6] = enable (=1) Bit[5:0] = value (0-64) Vtfl3 114[6:0] 64 The value in this register defines the Vtfl3 voltage (DAC setting) of kneepoint 2. Bit[6] = enable (=1) Bit[5:0] = value (0-64) The timing that needs to be applied in this external exposure mode looks like the one below. Frame_REQ T_EXP1 Total exposure time Exposure kp2 Exposure kp1 FIGURE 34: PIECEWISE LINEAR RESPONSE WITH EXTERNAL EXPOSURE MODE In this case the T_EXP1 pulses should be one CLK_IN period wide exactly. When shorter, they might not be detected and when longer, this will be seen as 2 (or more) pulses one after the other, which will not give a useable image. Please note, that a combination of the piecewise linear response and interleaved read-out is not possible. 5.3 WINDOWING To limit the amount of data or to increase the frame rate of the sensor, windowing in Y direction is possible. The number of lines and start address can be set by programming the appropriate registers. The CMV300 has the possibility to read out multiple (max=8) predefined subwindows in one read-out cycle. The default mode is to read-out one window with the full frame size (648 x 488). 5.3.1 SINGLE WINDOW When a single window is read out, the start address and size can be uploaded in the corresponding registers. The default start address is 0 and the default size is 488 (full frame). Windowing – single window Register name Register address Default value Description of the value start1 3-4 0 The value in this register defines the start address of the window in Y (min=0, max=487) Number_lines 1-2 488 The value in this register defines the number of lines read out by the sensor (min=1, max=488) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |