| поискавой системы для электроныых деталей |
|
AT45DB321E датащи(PDF) 36 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
AT45DB321E датащи(HTML) 36 Page - Renesas Technology Corp |
|
36 / 80 page ![]() DS-AT45DB321E-8784 Rev. N Page 36 9/1/23 © 2023 Renesas Electronics AT45DB321E Datasheet 8.2 Security Register The device contains a specialized Security Register that can be used for purposes such as unique device serialization or locked key storage. The register is comprised of a total of 128 bytes that is divided into two portions. The first 64 bytes (byte locations 0 through 63) of the Security Register are allocated as a One-Time Programmable space. Once these 64 bytes have been programmed, they cannot be erased or reprogrammed. The remaining 64 bytes of the register (byte locations 64 through 127) are factory programmed by Renesas Electronics and contains a unique value for each device. The factory programmed data is fixed and cannot be changed. Table 19. Security Register 8.2.1 Programming the Security Register The user programmable portion of the Security Register does not need to be erased before it is programmed. To program the Security Register, a four-byte opcode sequence of 9Bh, 00h, 00h, and 00h must be clocked into the device. After the last bit of the opcode sequence has been clocked into the device, the data for the contents of the 64-byte user programmable portion of the Security Register must be clocked in. After the last data byte has been clocked in, the CS pin must be deasserted to initiate the internally self-timed program cycle. The programming of the Security Register takes place in a time of tP, during which time the RDY/BUSY bit in the Status Register indicates that the device is busy. If the device is powered-down during the program cycle, then the contents of the 64-byte user programmable portion of the Security Register cannot be guaranteed. If the full 64 bytes of data are not clocked in before the CS pin is deasserted, then the values of the byte locations not clocked in cannot be guaranteed. Example: If only the first two bytes are clocked in instead of the complete 64 bytes, then the remaining 62 bytes of the user programmable portion of the Security Register cannot be guaranteed. Furthermore, if more than 64 bytes of data is clocked into the device, then the data wraps back around to the beginning of the register. For example, if 65 bytes of data are clocked in, then the 65th byte is stored at byte location 0 of the Security Register. Warning: The user programmable portion of the Security Register can only be programmed one time. Thus, it is not possible, for example, to only program the first two bytes of the register and then program the remaining 62 bytes at a later time. The Program Security Register command uses Buffer 1 for processing. Thus, the contents of Buffer 1 is altered from its previous state when this command is issued. Figure 14. Program Security Register Security Register Byte Number 0 1 · · · 63 64 65 · · · 127 Data Type One-Time User Programmable Factory Programmed by Renesas Electronics Data n 9Bh 00h 00h 00h Data n + 1 Data n + x CS SI Each transition represents eight bits |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |